288
X.io card
General
Typical operating voltages and current
consumption
Voltage
Current
Total power consumption: 4.0 watts
Environmental specifications
• Minimum/maximum card ambient operating temperatures: 0 to 55º C
• Minimum/maximum storage temperature: –40 to 75º C
• Maximum altitude for operation: 3,000 meters
• Maximum altitude for transport: 12,000 meters
• Operating humidity: 20 to 80% relative humidity (non-condensing)
• Storage humidity: 5 to 95% relative humidity (non-condensing)
¡ Important To avoid damage to your Matrox Axio components and/or
computer system, make sure that you don't operate your Axio cards at or
near the maximum operating temperature for a prolonged period of time (see
"Monitoring your Axio hardware operating temperatures"
more information).
Appendix C, Matrox Axio Specifications
PCI interface
Regulatory compliance
Nominal card dimensions
+3.3 V
0.26 A
Full-size PCI-X 66/100 MHz card
FCC Class A, CE Mark Class A, ACA Class A,
RoHS Directive 2002/95/EC
Card
12.2" × 4.2"
Card including bracket
Overall thickness including components
+5 V
+12 V
0.5 A
0.05 A
13.875" × 4.9"
0.75"
–12 V
0.0 A
on page
249
for
Need help?
Do you have a question about the Axio and is the answer not in the manual?