G.11 Changing The Type Of Detergent/Rinse Aid; G.12 Electrical Connections - Electrolux EFTD052E Installation Manual

Flight type dishwasher
Table of Contents

Advertisement

G.11 Changing the type of detergent/rinse aid

If changing to a different detergent/rinse aid type (even one by
the same manufacturer), you must rinse the suction and
pressure hoses with fresh water before connecting the new
detergent/rinse-aid container.
CAUTION
Mixing of different types of detergent/
rinse-aid will cause crystallization, which
may result in a breakdown of the dosing
pump. Failure to observe this condition
will invalidate the guarantee and product
liability.

G.12 Electrical connections

WARNING
Refer to "Safety Information".
CAUTION
The connection cable must be "H07RN-F"
type, oil proof. Tighten the cables properly
using a maximum torque of 6 Nm.
Make sure the machine power supply voltage specified on the
data plate matches the mains voltage C.3 Machine and
Manufacturer's identification data.
Make sure the system power supply is arranged and able to
take the actual current load and that it is executed in a
workmanlike manner according to the regulations in force in
the country of use.
The earth wire from the terminal board side must be longer
(max 20 mm) than the phase wires. Connect the power cable
earth wire to an efficient earth.
The machine must also be included in an equipotential system,
whose connection is made by means of screw EQ (see par.
Installation diagram) indicated by the symbol
equipotential wire must have a section of at least 10 mm
42
Connect the power cable to the equipment:
• Remove the top panel and insert the power supply cable
through the cable gland.
• Connect the power supply cable to the terminal block.
• When the terminal block is connected with the power cable,
check that the power supply voltage of each phases are the
same. If not set the transformer with the right voltage. Refer
to the picture below.
. The
Connect the modules electrically:
2
.
• Remove the back panels of each modules.
• Locate the coils of electrical cables of each modules.
• Refer the picture below to find the correct path to be
followed for each electrical cables.
• Always consult the electrical wiring diagram to connect
properly the electrical cables to the terminal board.
380-415
L1 L2 L3
PE
N

Advertisement