Put the corresponding Sanipure quantity in the Filtropure® measuring cap : 40mL for sparkling version and
13mL for non sparkling version. Connect the water cooler.
Open water inlet and let water circulates in the pipes.
Leave on for 5 minutes then drain the pipes of cold and ambient water circuits to eliminate all trace of pro-
duct. Run 2L of water in the ambient water circuit, 2L in the cold water circuit and 4L in the sparkling water
circuit. As a precaution, use PH test strip to make sure the water is perfectly good : the PH must be 7.
Leave on for 5 minutes and rinse at least 3L of water.

4. General checking

Check the water circuit and waterproofness.
Check the cooling unit.
Check water temperature and adjust if needed using the thermostat (Figure 13).
Check all buttons and the genral operation of the device.
5. Replacement of ToBeSure® system - Indicator TBS N°2
WARNING: the ToBeSure® system needs water to function correctly, for this reason there is an «exception» on the safety
system which is made during the first 15 seconds of dispensing. When installing make sure to run the water 15 seconds
before serving.
Disconnect water inlet and remove the circuit pressure by pressing on the distribution buttons. Disconnect
the water cooler's power cord.
Unscrew the manual screw to remove the top panel.
Loosen the 2 screws on each side of the distribution to remove the ToBeSure® system from its location
(Figure 14).
Disconnect the power cord and water inlet at the back of the device (Figure 15).
ATTENTION
:
some water can remain in the system, provide a small container (tray or glass) to empty the
excess water after disconnecting the system.
Remove the system from its place. To remove the protective case, slide it forward (Figure 16).
Put back the protective case on the new system and replace it in its place.
Replace the ToBeSure® system in its location with the 2 screws previously removed.
Reconnet the distribution adapter on the new system.
Reconnect the ToBeSure® system with water and electricity (Figure 15).
Put back the top panel.
Reopen water inlet and reconnect power supply.
Figure 15
MAINTENANCE
Figure 13
Figure 14
22
Figure 16