Operating indicators

INDICATOR
1.Water
2.UV
3.Drip-tray
4.Filter
5.CO2
6. Maintenance
USER GUIDE
1
2
STATE
OFF
Indicator N°1 & 6
flashing
ON
Safety shutdown : the dis-
Fixed ON + Indicator
tribution ran for more than
N°6 fixed ON
OFF
Flashing
ON
OFF
ON
OFF
ON
OFF
Flashing + Indicator N°6
ON
ON
OFF
Fixed ON
Keyboard connection loss
3
4
FUNCTION
No leaks
Leak
(only if option activated)
Lack of water
5min without interruption
UV lamp is working
UV lamp will be off soon
UV lamp is not working
OK
Drip-tray or dirp-tray
container is full
OK
Used filter
OK
Pump safety
CO2 cartrigdge empty
OK
14
5
6
SOLUTION
N/A
Turn off water supply.
General device inspection.
Check that the water cooler is well connected to
water supply, That water pressure is set at 3 bars
+/- 0,5 bars.
Check that the Watersafe® antileak system is
well connected.
Disconnect the water cooler. Wait for 1 min and
reconnect it.
Plan the replacement of ToBeSure® disinfection
system.
Change the ToBeSure® disinfection system.
Empty the drip-tray / container.
Maintenance & replacement of the filter.
Do not forget to Reset (see page ...).
The pump has been running continuously for
more than 5 minutes causing the fountain to shut
down. Disconnect the device, wait for 1min and
reconnect it.
Remplace the cartridge.
Call a qualified technician for diagnosis and
maintenance.