Description of the numbered areas
1. Enter a channel name that shall not be any one of the names in use
2. Describe the channel
3. To enable the channel or not (Yes by default)
4. Select a protocol type from the drop-down list based on the model of the data
collection device (the protocols are supported by the .ipk file installed)
For certain protocol, more configuration parameters are required. Taking Modbus RTU
protocol as an example, further information is needed.
Description of the numbered areas
4. Select Modbus protocol from the drop-down list
5. Choose serial communication (TCP communication also available)
6. Both Modbus RTU and Modbus ASCII are available (Modbus RTU for illustration)
7. Select related serial port as identified by the device manager
8. Determine the mode of the serial port (the options vary with the gateway model)
9. Choose the baud rate
10. The data bit in communication (8 bits for RTU communication by default)
11. There are three parity bits: even, odd, and non-parity
12. The stop bit represents the last bit in a single package, and the typical value includes 1,
1.5 and 2
13. Select to enable request to send (RTS) protocol or not
C335 Series Edge Computing Gateways | User Manual