COM1 could switch between RS232 and RS485 (default).
Input the following command lines in a host device to enable RS232 on COM1 and use a
serial communication program (e.g., microcom) to open the port:
~# gpio set uart0 rs232 save
Or
~# gpio set uart0 rs232
~# gpio get uart0
rs232
~# microcom /dev/ttyO2 -s 115200
Input the following command lines in a host device to enable RS485 on COM1 and use a
serial communication program (e.g., microcom) to open the port:
~# gpio set uart0 rs485 save
Or
~# gpio set uart0 rs485
~# gpio get uart0
rs485
~# microcom /dev/ttyO2 -s 115200