Download Print this page

SIGNIFY LUMEC HighFocus Plus Installation Instruction

Advertisement

Available languages

Available languages

Quick Links

IMPORTANT: FOR YOUR PROTECTION, YOU MUST CAREFULLY READ ALL WARNINGS AND INSTRUCTIONS IN THEIR
ENTIRETY PRIOR TO INSTALLATION, OPERATION, SERVICE OR MAINTENANCE. FAILURE TO DO SO CAN RESULT IN DEATH,
PERSONAL INJURY AND PROPERTY DAMAGE. If you do not understand these warnings and instructions, or if additional
information is desired, please contact Signify, Lumec.TSC@signify.com phone 1-833-744-6439.
Installation, service and maintenance of luminaires must be performed by a qualified professional and in accordance with all federal, state and local
laws, regulations and electrical codes. This professional should be familiar with the construction and operation of this product and any hazards
involved. If not qualified, do not attempt installation, service or maintenance.
To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts, abrasions and other hazards, please read
all warnings and instructions included with the luminaire, on the luminaire's packaging and affixed to the luminaire itself.
Maintenance of the luminaires should be performed by person(s) familiar with the luminaire's construction and operation and any hazards involved.
WARNING
RISK OF FIRE, ELECTRIC SHOCK OR PERSONAL INJURY
Disconnect or turn off power before attempting any installation, service or
maintenance.
Verify that supply voltage is correct by referencing the luminaire label
information.
Make all electrical and ground connections in accordance with the National
Electrical Code (NEC) and any other applicable laws, regulations or codes.
All wiring connections should be capped with UL-approved wire connectors.
WARNING
RISK OF FIRE OR PERSONAL INJURY
Keep combustible materials away from LED/lamp & lens
Do not operate in close proximity to persons, combustible materials
or substances affected by heat or drying.
CAUTION
RISK OF PRODUCT DAMAGE
• Never connect luminaires and/or components under load with supply voltage turned on.
• Do not mount or support these luminaires in a manner that can cut the outer jacket or damage wire insulation.
• Do not restrict fixture ventilation. Allow for some volume of airspace around luminaire. Avoid covering luminaire with insulation, foam or other material that will
prevent convection or conduction cooling.
• Do not exceed luminaire maximum ambient temperature.
• Do not modify the luminaire.
• Only use luminaire in its intended application and location.
• LED products are polarity sensitive. Ensure proper polarity before installation.
• Electrostatic Discharge (ESD) can damage LED. Personal grounding equipment must be worn during all installation and servicing of the luminaire.
• Do not touch individual electrical components as this can cause ESD, shorten LED life, or impact LED performance.
• Some components inside the luminaire may not be serviceable. In the unlikely event your luminaire may require service, stop using it immediately and contact
Signify.
• Always read the luminaires complete installation instructions prior to installation for any additional luminaire specific warnings.
• In the case of HID or Fluorescent luminaires, regular re-lamping is required to keep luminaire operating within safe limits.
• Do not install damaged product. Handling and installing damaged products can potentially increase the risks mentioned In case of damage and/or missing parts
upon arrival of the luminaire.
• These instructions do not purport to cover all details or variations in equipment nor to provide every possible contingency to meet in connection with installation,
operation or maintenance.
• Please see luminaire specific Installation and Maintenance Instruction for additional warnings or any applicable FCC or regulatory statements. Failure to follow
any of these Instructions could void luminaires warranties.
Luminaire Maintenance
• Regular luminaire maintenance programs are recommended.
• It is recommended to clean the outside of the luminaire and the refractor/lens.
• Frequency of cleaning will depend on ambient dirt level and minimum light output which is acceptable to user.
• If clean water is not sufficient for cleaning, use a neutral, synthetic, not-scratching and not-abrasive cleaning substance.
• Never use alkaline and/or acetous cleaning substances.
• Make sure that the cleaning substance is carefully removed by rinsing with lots of clean water.
• Signify recommends using a cleaning solution that has a PH between 5 and 8.
• Recycle: For information on how to recycle electronic products and components, please visit www.epa.gov.
1/13/2023
page
1
www.lumec.com
HFP
HighFocus Plus
Installation Instruction
WARNING
RISK OF FIRE, ELECTRIC SHOCK OR PERSONAL INJURY
Wear gloves and safety glasses at all times when removing luminaire
from carton, installing, servicing or performing maintenance.
Avoid direct eye exposure to the light source while it is on.
WARNING
RISK OF FIRE, ELECTRIC SHOCK OR PERSONAL INJURY
Allow LED/lamp & lens to cool before handling.
Do not touch enclosure or light source
Do not exceed maximum wattage marked on luminaire label.
Follow all manufacturer's warnings, recommendations, instructions
and restrictions for driver type, burning position, mounting locations
and replacement.
442295981861

Advertisement

loading
Need help?

Need help?

Do you have a question about the LUMEC HighFocus Plus and is the answer not in the manual?

Questions and answers

Summary of Contents for SIGNIFY LUMEC HighFocus Plus

  • Page 1 • Make sure that the cleaning substance is carefully removed by rinsing with lots of clean water. • Signify recommends using a cleaning solution that has a PH between 5 and 8. • Recycle: For information on how to recycle electronic products and components, please visit www.epa.gov.
  • Page 2: Installation Instructions

    Installation Instructions 442295981861 It is recommended that two people perform IP-65 this operation. Unscrew door screw and open gently the access door. Disconnect power and slide the fixture onto the tenon. See table for approximate penetration. Horizontal angle can be adjusted in 2.5° steps. Evenly tighten all 3/8-16 bolts of the tenon bracket.
  • Page 3 Installation Instructions 442295981861 Tenon bracket bolts (4x 3/8-16) Tenon penetration Tilt angle: Penetration: -5.0⁰ 7-1/4’’ -2.5⁰ 6-7/8’’ 0⁰ 6-3/8’’ +2.5⁰ 6.0’’ +5.0⁰ 5-5/8’’ Tighten the bolts to 168 lbs.in (14 lbs.ft) -5° 0° -2.5° 2.5° 5° FAWS (option) For safety reasons, the ground leads must always be connected before any other leads.
  • Page 4 Si des renseignements additionnels sont requis, ou si des problèmes particuliers surviennent qui ne sont pas couverts suffisamment aux fins prévues par l’acheteur ou le propriétaire, veuillez soumettre la question ou le problème à avec Signify TSC@signify.com composez le 1-833-744-6439.
  • Page 5: Instructions D'installation

    Instructions d’installation 442295981861 Il est recommandé que cette operation soit IP-65 effectuée par deux personnes. Dévissez la vis de fermeture de la porte et ouvrez avec précaution la porte d'accès. Débranchez l'alimentation et faites glisser l'appareil sur le tenon. Voir le tableau pour la pénétration approximative. L'angle horizontal peut être réglé...
  • Page 6 Instructions d’installation 442295981861 Pénétration du tenon Boulons du support du tenon (4x 3/8-16) Angle d’inclinaison: Pénétration: -5.0⁰ 7-1/4’’ -2.5⁰ 6-7/8’’ 0⁰ 6-3/8’’ +2.5⁰ 6.0’’ +5.0⁰ 5-5/8’’ Serrez les boulons à 168 lbs.in (14 lbs.ft) -5° 0° -2.5° 2.5° 5° FAWS (option) Pour des raisons de sécurité, les fils de terre doivent toujours être connectés avant tout autre fil.