Download Print this page
SIGNIFY GARDCO Pureform P15 Manual
Hide thumbs Also See for GARDCO Pureform P15:

Advertisement

Available languages

Available languages

Quick Links

IMPORTANT: FOR YOUR PROTECTION, YOU MUST CAREFULLY READ ALL WARNINGS AND INSTRUCTIONS IN THEIR ENTIRETY
PRIOR TO INSTALLATION, OPERATION, SERVICE OR MAINTENANCE. FAILURE TO DO SO CAN RESULT IN DEATH, PERSONAL INJURY
AND PROPERTY DAMAGE. If you do not understand these warnings and instructions, or if additional information is desired,
please contact Signify at SanMarcos.TSC@Signify.com phone 800‐227‐0758
Installation, service and maintenance of luminaires must be performed by a qualified professional and in accordance with all federal, state and local laws, regulations and
electrical codes. This professional should be familiar with the construction and operation of this product and any hazards involved. If not qualified, do not attempt
installation, service or maintenance.
To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts, abrasions and other hazards, please read all warnings and
instructions included with the luminaire, on the luminaire's packaging and affixed to the luminaire itself.
Maintenance of the luminaires should be performed by person(s) familiar with the luminaire's construction and operation and any hazards involved.
The light source and/or control gear and/or the external flexible cable contained in this luminaire shall only be replaced by the manufacturer or his service agent or a similar
qualified person.
WARNING
RISK OF FIRE, ELECTRIC SHOCK OR PERSONAL INJURY
Disconnect or turn off power before attempting any installation, service or
maintenance.
Verify that supply voltage is correct by referencing the luminaire label
information.
Make all electrical and ground connections in accordance with the National
Electrical Code (NEC) and any other applicable laws, regulations or codes.
All wiring connections should be capped with UL-approved wire connectors.
WARNING
RISK OF FIRE OR PERSONAL INJURY
Keep combustible materials away from LED/lamp & lens
Do not operate in close proximity to persons, combustible materials
or substances affected by heat or drying.
CAUTION
RISK OF PRODUCT DAMAGE
• Never connect luminaires and/or components under load with supply voltage turned on.
• Do not mount or support these luminaires in a manner that can cut the outer jacket or damage wire insulation.
• Do not restrict fixture ventilation. Allow for some volume of airspace around luminaire. Avoid covering luminaire with insulation, foam or other material that will
prevent convection or conduction cooling.
• Do not exceed luminaire maximum ambient temperature.
• Do not modify the luminaire.
• Only use luminaire in its intended application and location.
• Led products are polarity sensitive. Ensure proper polarity before installation.
• Electrostatic Discharge (ESD) can damage LED. Personal grounding equipment must be worn during all installation and servicing of the luminaire.
• Do not touch individual electrical components as this can cause ESD, shorten LED life, or impact LED performance.
• Some components inside the luminaire may not be serviceable. In the unlikely event your luminaire may require service, stop using it immediately and contact
Signify.
• Always read the luminaires complete installation instructions prior to installation for any additional luminaire specific warnings.
• Do not install damaged product. Handling and installing damaged products can potentially increase the risks mentioned In case of damage and/or missing parts
upon arrival of the luminaire.
• These instructions do not purport to cover all details or variations in equipment nor to provide every possible contingency to meet in connection with installation,
operation or maintenance.
• Please see luminaire specific Installation and Maintenance Instruction for additional warnings or any applicable FCC or regulatory statements. Failure to follow
any of these Instructions could void luminaires warranties.
Luminaire Maintenance
• Regular luminaire maintenance programs are recommended.
• It is recommended to clean the outside of the luminaire and the refractor/lens.
• Frequency of cleaning will depend on ambient dirt level and minimum light output which is acceptable to user.
• If clean water is not sufficient for cleaning, use a neutral, synthetic, not-scratching and not-abrasive cleaning substance.
• Never use alkaline and/or acetous cleaning substances.
• Make sure that the cleaning substance is carefully removed by rinsing with lots of clean water.
• Signify recommends using a cleaning solution that has a PH between 5 and 8.
• Recycle: For information on how to recycle electronic products and components, please visit www.epa.gov.
3/6/2024
page
1
www.gardcolighting.com
Pureform
P15 & P20
443561211650-Rev B
WARNING
RISK OF FIRE, ELECTRIC SHOCK OR PERSONAL INJURY
Wear gloves and safety glasses at all times when removing luminaire
from carton, installing, servicing or performing maintenance.
Avoid direct eye exposure to the light source while it is on.
WARNING
RISK OF FIRE, ELECTRIC SHOCK OR PERSONAL INJURY
Allow Led/lamp & lens to cool before handling.
Do not touch enclosure or light source
Do not exceed maximum wattage marked on luminaire label.
Follow all manufacturer's warnings, recommendations, instructions
and restrictions for driver type, burning position, mounting locations
and replacement.
443561211650-Rev B

Advertisement

loading
Need help?

Need help?

Do you have a question about the GARDCO Pureform P15 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for SIGNIFY GARDCO Pureform P15

  • Page 1 • Make sure that the cleaning substance is carefully removed by rinsing with lots of clean water. • Signify recommends using a cleaning solution that has a PH between 5 and 8. • Recycle: For information on how to recycle electronic products and components, please visit www.epa.gov.
  • Page 2 443561211650-Rev B P15-C Series with Comfort P15-C Series with LED Engine Precision LED Engine P20-P Series with P20-C Series with Precision LED Engine ComfortEdge Technology page...
  • Page 3 RETRO FIT ARM MOUNT INSTALLATION INSTRUCTIONS 443561211650-Rev B REQUIRED TOOLS: 9/16" SOCKET/OPEN-END WRENCH & #2 PHILLIPS-HEAD SCREWDRIVER BOLSTER PLATE STEP 1: ASSEMBLE BOLSTER PLATE Attach cage nut to the bolster plate provided. Hold bolster CAGE NUT plate inside pole with top hole aligned with top mounting hole in pole.
  • Page 4 EMERGENCY INSTALLATION(COMFORT) 443561211650-Rev B MUST CONNECT EMERGENCY SWITCH TO DRIVER CHARGE EMERGENCY EMERGENCY BATTERY BATTERY BACK DRIVER EMERGENCY TEST SWITCH AND INDICATOR LIGHT EMERGENCY BATTERY PACK LUMINAIRES WILL HAVE ONE EXTRA WIRE EXITING THE FIXTURE (RED). MAKE SUPPLY WIRE CONNECTIONS ACCORDING TO THE APPROPRIATE WIRING DIAGRAM ABOVE. LUMINAIRES THAT WILL BE SWITCHED ON/OFF MUST HAVE THE RED LEAD CONNECTED TO AN UNSWITCHED INPUT LINE LEAD SO SWITCHING THE LUMINAIRE OFF IS NOT SEEN AS A POWER FAILURE.
  • Page 5 EMERGENCY INSTALLATION(COMFORT)(EBPC) 443561211650-Rev B MUST CONNECT SWITCH TO CHARGE EMERGENCY BATTERY BACK EMERGEMCY DRIVER EMERGENCY BATERIES LED DRIVER EMERGENCY TEST SWITCH AND INDICATOR LIGHT EMERGENCY BATTERY PACK LUMINAIRES WILL HAVE ONE EXTRA WIRE EXITING THE FIXTURE (RED). MAKE SUPPLY WIRE CONNECTIONS ACCORDING TO THE APPROPRIATE WIRING DIAGRAM ABOVE. LUMINAIRES THAT WILL BE SWITCHED ON/OFF MUST HAVE THE RED LEAD CONNECTED TO AN UNSWITCHED INPUT LINE LEAD SO SWITCHING THE LUMINAIRE OFF IS NOT SEEN AS A POWER FAILURE.
  • Page 6 EMERGENCY INSTALLATION (PIXELATED) 443561211650-Rev B EMERGENCY LED DRIVER WITH INTEGRATED BATTERY DRIVER MUST CONNECT SWITCH TO CHARGE EMERGENCY TEST SWITCH EMERGENCY AND INDICATOR LIGHT BATTERY BACK EMERGENCY BATTERY PACK LUMINAIRES WILL HAVE ONE EXTRA WIRE EXITING THE FIXTURE (RED). MAKE SUPPLY WIRE CONNECTIONS ACCORDING TO THE APPROPRIATE WIRING DIAGRAM ABOVE.
  • Page 7 © 2022 Signify Holding. All rights reserved. The information provided herein is subject Signify North America Corporation Signify Canada Ltd. to change, without notice. Signify does not give any representation or warranty as to 400 Crossing Blvd, Suite 600 281 Hillmount Road,...
  • Page 8 Veillez à ce que la substance nettoyante soit éliminée à fond en rinçant la surface à grande eau propre. Signify recommande d’utiliser une solution de nettoyage au pH entre 5 et 8. Recyclez : Pour obtenir des renseignements sur la façon de recycler les produits et les composants électroniques, veuillez visiter www.epa.gov...
  • Page 9 443561211650-Rev B P15C avec Comfort P15P avec Precision LED Engine LED Engine P20C avec ComfortEdge P20P avec Precision Technology LED Engine page...
  • Page 10 INSTRUCTION D’INSTALLATION POUR BRAS DE FIXATION DE MODERDISATION (RAM) 443561211650-Rev B OUTILS NÉCESSAIRES : DOUILLE OU CLÉ PLATE DE 9/16 PO ET TOURNEVIS À TÊTE PHILLIPS N° 2 HAUT PLATEAU DE ÉTAPE 1: ASSEMBLAGE DU PLATEAU DE SOUTIEN SOUTIEN Fixez l'écrou de cage à la plaque de traversin fournie. Tenez la plaque de ÉCROU À...
  • Page 11 INSTALLATION D’URGENCE (COMFORT) 443561211650-Rev B PILOT D’URGENC BLOC DE DOIT RACCORDER BATTERIES L’INTERRUPTEUR D’UREGENCE POUR CHARGER LE BLOC-BATTERIES CIRCUIT D’URGENCE. D’ATTAQUE DEL COMMUTATEUR DE TEST D’URGENCE ET TÉMOIN INDICATEUR LES LUMINAIRES AVEC BLOC-BATTERIES D’URGENCE PRÉSENTENT UN FIL SUPPLÉMENTAIRE QUI SORT DE L’APPAREIL (ROUGE).
  • Page 12 INSTALLATION D’URGENCE (COMFORT)(EBPC) 443561211650-Rev B PILOT DOIT RACCORDER D’URGENCE L’INTERRUPTEUR BLOCS DE POUR CHARGER LE BATTERIES BLOC-BATTERIES D’URGENCE D’URGENCE. CICUIT D’ATTAQUE COMMUTATEUR DE TEST D’URGENCE ET TÉMOIN INDICATEUR LES LUMINAIRES AVEC BLOC-BATTERIES D’URGENCE PRÉSENTENT UN FIL SUPPLÉMENTAIRE QUI SORT DE L’APPAREIL (ROUGE).
  • Page 13 INSTALLATION D’URGENCE (PIXELATED) 443561211650-Rev B DOIT RACCORDER PILOT D’URGENCE L’INTERRUPTEUR AVEC BATTERIES POUR CHARGER LE INTÉGRÉES BLOC-BATTERIES D’URGENCE. CIRCUIT D’ATTAQUE DEL COMMUTATEUR DE TEST D’URGENCE ET TÉMOIN INDICATEUR LES LUMINAIRES AVEC BLOC-BATTERIES D’URGENCE PRÉSENTENT UN FIL SUPPLÉMENTAIRE QUI SORT DE L’APPAREIL (ROUGE).
  • Page 14 © 2023 Signify Holding. Tous droits réservés. L’information retrouvée dans la présente Signify North America Corporation Signify Canada Ltd. est sujette à changement sans préavis. Signify ne fait aucune déclaration ni ne donne 400 Crossing Blvd, Suite 600 281 Hillmount Road, 2021 aucune garantie quant à...