Download Print this page
Eaton Mini PDU Installation And Operation Manual

Eaton Mini PDU Installation And Operation Manual

30 kva mini power distribution unit

Advertisement

Quick Links

Eaton
©
30 kVA Mini Power Distribution Unit
Installation and Operation Manual
p/n: 164001117
Revision 01

Advertisement

loading
Need help?

Need help?

Do you have a question about the Mini PDU and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Eaton Mini PDU

  • Page 1 Eaton © 30 kVA Mini Power Distribution Unit Installation and Operation Manual p/n: 164001117 Revision 01...
  • Page 2 PDI, JCOMM, Quad-Wye, ToughRail Technology, and WaveStar are registered trademarks of Power Distribution Inc. All other trademarks are property of their respective companies. ©Copyright 2023 Eaton, Raleigh, NC, USA. All rights reserved. No part of this document may be reproduced in any way without the express written approval of Eaton.
  • Page 3 Dear Customer, On behalf of everyone at Eaton, we thank you for partnering with us, and trusting us to maintain your business continuity and preventing downtime at your facility. Our suite of backup power, power distribution and power management products are designed to protect you from a host of threats including power outages, surges, lighting strikes, and enable you to monitor and control your power infrastructure.
  • Page 4: Firmware License

    Licensee or other subsidiary of Licensee’s parent, to copy, distribute, or otherwise transfer the Firmware without the prior written consent of Eaton. Licensee may transfer the Firmware directly to a third party only in connection with the sale of the Eaton product in which it is installed.
  • Page 5: General Provisions

    TO THE EXTENT PERMITTED BY APPLICABLE LAW, THE USE OF THE PRODUCT IS AT LICENSEE’S SOLE RISK. 5.0 GENERAL PROVISIONS 5.1 Update Policy. Eaton may from time to time, but has no obligation to, create Updates of the Firmware or components thereof. 5.2 Limitation on Liability. NOTWITHSTANDING ANY PROVISION OF THIS AGREEMENT TO THE...
  • Page 6 Firmware pursuant to license arrangements between Eaton and such third parties. Third Party Licensor components in the Firmware are not licensed or warranted under the terms of this document, but are instead subject to the Third Party Licensors’...
  • Page 7 Eaton, the disclosure of which would cause substantial harm to Eaton that could not be remedied by the payment of damages alone and such confidential aspects of the Firmware shall not be disclosed to third parties without the prior written consent of Eaton.
  • Page 9 7 7 A A p p p p e e n n d d i i x x : : 3 3 0 0 k k V V A A M M i i n n i i P P D D U U D D r r a a w w i i n n g g s s ............................................1 1 9 9 Eaton 30 kVA Mini Power Distribution Unit Installation and Operation Manual 164001117—Rev 01...
  • Page 10 Table of Contents Eaton 30 kVA Mini Power Distribution Unit Installation and Operation Manual 164001117—Rev 01...
  • Page 11 Mini PDU Output Receptacles ......................12 Figure 8. Cable Servers to Mini PDU ......................13 Figure 9. Mini PDU Locking Doors........................ 15 Figure 10. Mini PDU Circuit Breakers......................16 Eaton 30 kVA Mini Power Distribution Unit Installation and Operation Manual 164001117—Rev 01...
  • Page 12 List of Figures Eaton 30 kVA Mini Power Distribution Unit Installation and Operation Manual 164001117—Rev 01...
  • Page 13 I I n n t t e e n n d d e e d d U U s s e e The 30 kVA Mini PDU can be placed next to server racks, providing local power distribution. The unit has casters and is easily repositioned.
  • Page 14 Storage temperature range must be within these extremes: -30⁰C to +70⁰C (-22⁰F to 158⁰F). If the transformer has been exposed to moisture, it should be dried out before being energized. Consult Eaton Service if the unit has been exposed to moisture or contamination.
  • Page 15 1 1 . . 8 8 W W a a r r r r a a n n t t y y To view the warranty please click on the link or copy the address to download from the Eaton website: UPS Product Warranty https://www.eaton.com/content/dam/eaton/products/backup-power-ups-surge-it-power-distribution/backup-...
  • Page 16 Introduction Eaton 30 kVA Mini Power Distribution Unit Installation and Operation Manual 164001117—Rev 01...
  • Page 17 Install equipment in an appropriate electrical environment per local regulations. • Disconnect and lock-out all power supplying equipment before working on or installing components. Use a properly rated voltage sensing device to confirm power is OFF. Eaton 30 kVA Mini Power Distribution Unit Installation and Operation Manual 164001117—Rev 01...
  • Page 18 Safety Eaton 30 kVA Mini Power Distribution Unit Installation and Operation Manual 164001117—Rev 01...
  • Page 19 Accessories may be shipped on the same pallet or separately. For moving the Mini PDU on its pallet, Eaton recommends that you leave the retaining bands intact until you have moved the unit to a convenient location for removing it from its pallet.
  • Page 20: Installation

    M M o o v v i i n n g g a a n n d d P P l l a a c c i i n n g g t t h h e e M M i i n n i i P P D D U U Move the Mini PDU off its pallet with a forklift as follows: The Mini PDU is attached to its pallet by its seismic brace with wood screws. With the pallet resting on the floor, remove the wood screws.
  • Page 21 Screw, 3/8”-16 X .75” lg., Hex Hd, Serrated Flange, Steel) The Cable Ladder should also be supported by attaching the top of the Cable Ladder to the customer’s cable trough. Eaton 30 kVA Mini Power Distribution Unit Installation and Operation Manual 164001117—Rev 01...
  • Page 22 Bracket’s Part Number = MIS68130 PEM nuts. • A licensed electrician must install the Mini PDU and connect external cables and wiring. • Installers should use Lock-Out/Tag-Out procedures and observe other precautions listed in the introductory Safety section.
  • Page 23 C C o o n n n n e e c c t t I I n n p p u u t t P P o o w w e e r r C C a a b b l l e e The Mini PDU has an input cable connected to the main input circuit breaker. (For shipping, the input cable may be partially inserted into the Output Cable Entry tray.
  • Page 24 C C o o n n n n e e c c t t O O u u t t p p u u t t P P o o w w e e r r C C a a b b l l e e s s The Mini PDU has (20) output receptacles ((16) x 30A, (4) x 20A) in the rear of the unit, numbered to correspond to front panelboard circuit breakers.
  • Page 25 Run the cable through the Cable Entry Brush Panel to the correct output receptacle. Connect to the receptacle and lock. Figure 8. Cable Servers to Mini PDU Eaton 30 kVA Mini Power Distribution Unit Installation and Operation Manual 164001117—Rev 01...
  • Page 26 Power Cabling Eaton 30 kVA Mini Power Distribution Unit Installation and Operation Manual 164001117—Rev 01...
  • Page 27: Front Doors

    5 5 . . 1 1 A A c c c c e e s s s s The Mini PDU has (2) locking doors in the front of the unit: • Clear Lexan door to access circuit breaker panelboard.
  • Page 28 Operation Figure 10. Mini PDU Circuit Breakers Main Input Circuit Breaker Subfeed (Secondary) Circuit Breaker Panelboard Circuit Breakers Eaton 30 kVA Mini Power Distribution Unit Installation and Operation Manual 164001117—Rev 01...
  • Page 29 C C h h a a p p t t e e r r 6 6 E E a a t t o o n n S S e e r r v v i i c c e e C C o o n n t t r r a a c c t t s s Eaton Service contracts help to provide the added insurance that the reliability of your critical power systems is intact.
  • Page 30 Eaton Service Contracts Eaton 30 kVA Mini Power Distribution Unit Installation and Operation Manual 164001117—Rev 01...
  • Page 31 C C h h a a p p t t e e r r 7 7 A A p p p p e e n n d d i i x x : : 3 3 0 0 k k V V A A M M i i n n i i P P D D U U D D r r a a w w i i n n g g s s Eaton 30 kVA Mini Power Distribution Unit Installation and Operation Manual 164001117—Rev 01...
  • Page 32 Appendix: 30 kVA Mini PDU Drawings Eaton 30 kVA Mini Power Distribution Unit Installation and Operation Manual 164001117—Rev 01...
  • Page 33 Appendix: 30 kVA Mini PDU Drawings Eaton 30 kVA Mini Power Distribution Unit Installation and Operation Manual 164001117—Rev 01...
  • Page 34 Appendix: 30 kVA Mini PDU Drawings Eaton 30 kVA Mini Power Distribution Unit Installation and Operation Manual 164001117—Rev 01...
  • Page 35 Appendix: 30 kVA Mini PDU Drawings Eaton 30 kVA Mini Power Distribution Unit Installation and Operation Manual 164001117—Rev 01...
  • Page 36 16400111701 164001117 01...

This manual is also suitable for:

11900003