Other Settings - Oilon EasyAce Operation Manual

Hide thumbs Also See for EasyAce:
Table of Contents

Advertisement

Time between starts
Inhibit start time
Time to next start

3.5 Other settings

This option shows usage information across the unit's entire operating history as well as for the current
year and the previous three full years.
Heating
Hot water
Electricity
Additional heating
Compressor running
time
Compressor times
started
Heating
Hot water
Electricity
History
The above information shown for the previous three full years, broken down by the year.
See section Heating.
See section Domestic hot water.
Heat pump
20 (49)
Device settings → Hot water → Settings → Legionella inhibition
Status view → Hot water → Settings → Legionella inhibition
The interval between heating periods. This interval depends on the domestic hot
water temperature setting.
● Typical setting: 3–7 days
● With lukewarm domestic hot water, use a shorter interval.
The time of day when the function is activated. Select a time when domestic hot
water is not typically used, such as nighttime hours.
The number of days (d) before the function is activated again.
Device settings → Usage info
An estimate of the space heating energy produced.
An estimate of the energy produced for heating domestic hot water.
An estimate of the compressor's and the electric heater's power consumption.
An estimate of the electric heater's power consumption.
The number of hours the compressor has been in operation.
The number of times the compressor has started.
Device settings → Usage info → Current year
An estimate of the space heating energy produced within the current year.
An estimate of the energy produced for heating domestic hot water within the current
year.
An estimate of the compressor's and the electric immersion heater's power
consumption within the current year.
Device settings → Heating circuits
Device settings → Hot water
Device settings → Operating mode
Off
The heat pump's compressor and electric immersion heater are off.
In use
The heat pump is on. The electric immersion heater can also be used (if allowed by
the operating mode).
Additional heater only
Only the unit's internal electric immersion heater is used for heating. The
compressor and the brine circuit are not in use.
M8004 2308EN