3.4 Domestic hot water

Domestic hot water view
Current operating
1
mode
Domestic hot water
tank's heating
water flow and
2
return temperature
(condenser out and
condenser in)
Target temperature
for domestic hot
3
water tank and
condenser pump
speed
Domestic hot water settings
Setpoints for
operating modes
(pos. 5)
Schedule for
operating modes
(pos. 7)
Hot water heating
This function heats up the domestic hot water to a high temperature to prevent bacterial growth.
Temperature is kept at a high level for a clean-up period. To achieve sufficient temperature levels, the
domestic hot water in the tank can be heated up using both the compressor and the unit's electric heater.
● If domestic hot water temperature remains mostly at or above +55 °C, the function is usually not
necessary.
● The boost function can be used only if using the electric heater for heating domestic hot water has
been enabled (i.e. the additional heater's Mode for hot water setting is either Inhibition, After
compressor, or With compressor).
Inhibition
M8004 2308EN
Device settings → Hot water
Status view → Hot water
There are three operating modes for domestic hot water heating: Normal, Boost,
and Reduced. See section Home or Away function and Schedules.
The Boost function can be used only if using the in-line heater for domestic hot
water heating has been enabled (i.e. the additional heater's Mode for hot water
setting is either After compressor or With compressor).
See section Home or Away function and Schedules.
Device settings → Hot water → Settings
Status view → Hot water → Settings
In use
Domestic hot water heating is enabled.
Off
Domestic hot water heating is disabled.
Device settings → Hot water → Settings → Legionella inhibition
Status view → Hot water → Settings → Legionella inhibition
Off
Legionella inhibition is disabled.
In use
Legionella inhibition is enabled.
4 Settings
Target temperature
for each domestic
5
hot water tank
operating mode
DHW storage tank
6
temperature
Schedule for
7
operating modes
19 (49)