If room temperature optimization is enabled, the view will show the current room
temperature as well as the room temperature target values for each operating mode.
1 Heating curve
Current operating
2
mode
Circuit flow
3
temperature and
target temperature
Heating circuit
pump speed (if the
4
circuit has its own
pump)
Schedule for
5
operating modes
Heating curve
The heating curve determines the flow temperature: the temperature of water pumped
into the heating circuit at different outdoor temperature points. Usually, the installation
company takes care of heating curve configuration.
The heating curve consists of six adjustable points. Curve values should be tuned in
during the first few heating seasons.
The impact of different operating modes
There are three operating modes for space heating: Normal, Boost, and Reduced
(see section Home or Away function and Schedules).
No room temperature measurement available or
temperature optimization disabled
Room temperature optimization disabled
The selected operating mode will either increase (+) or decrease (–) the target flow
temperature by a set amount. This influences room temperature indirectly, see the table
below.
16 (49)
Room temperature measurement active and
temperature optimization enabled
6 Settings
The impact of
7
different operating
modes
8 Room temperature
M8004 2308EN