Front Panel Of A Bim - Nortel 15000 Hardware Description

Multiservice switch
Hide thumbs Also See for 15000:
Table of Contents

Advertisement

Combinations of BIMs in a BIP
Shelf type
PEC of a BIP
with BIM
combinations
Multiservice
NT6C62
Switch 15000
Multiservice
AP6C68
Switch 20000
Since there is no visible exterior difference between the BIM faceplates on
either type of switch, you must refer to the part number on the label of each
unit.

Front panel of a BIM

The front panel of each breaker interface module (BIM) includes
a triangular alarm LED
a rectangular power LED
five PCB circuit breakers (four 20 A and one 5 A)
— for a Multiservice Switch 15000, four 20 A and one 5 A
— for a Multiservice Switch 20000, four 25 A and one 5 A
a captive screw to hold the module in place
There is no visible exterior difference between the BIM faceplate of either type
of switch.
The different states of the LEDs are listed in the table
indicators for BIMs (page 45)
BIMs (page
Copyright © 2005, Nortel Networks
- 44 -
Breaker interface panel
PECs of the BIM pairs that can be installed
two or four 20-amp NT6C60PA for one or two nodes
or
two 20-amp NT6C60PA for a Multiservice Switch 15000 in the
lower half of the NEBS 2000 frame and
two 25-amp AP6C67PA for a Multiservice Switch 20000 in the
upper half of the NEBS 2000 frame
two or four 25-amp AP6C67PA for one or two nodes
or
two 25-amp AP6C67PA for a Multiservice Switch 20000 in the
lower half of the NEBS 2000 frame and
two 20-amp NT6C60PA for a Multiservice Switch 15000 in the
upper half of the NEBS 2000 frame
and the table
45).
Nortel Networks Multiservice Switch 15000/20000
Hardware Description
NN10600-120 sPCR6.1S1 Standard
sPCR6.1 February 2005
Alarm LED status
Power LED status indicators for
Nortel Networks Confidential