Reed switch and namur pulsers for sj plus single jet water meter (2 pages)
Summary of Contents for MADDALENA ElecTo SJ
Page 1
ElecTo SJ Electronic single jet meter Code INSTRUCTIONS FOR INSTALLATION, USE AND MAINTENANCE Translation of the original instructions. Before installing and using the device, carefully read this manual and store it together with the product. Code 5000090C - 03/2023 - R5...
Compliance Contents Maddalena S.p.A. declares that ElecTo SJ General information ......3 Warnings and safety rules ......3 is compliant with the mandatory require- Restrictions ...........4...
– This device is not intended for use – The device must be used as intend- by persons with reduced mental or ed by Maddalena S.p.A., which motor capacities, or lack of experi- is not liable for damage caused to...
1.2 Restrictions 1.3 Device description ElecTo SJ is a single-jet meter with mechan- PROHIBITED ical movement and fully electronic timing devices designed for measuring hot and – Modify and/or attempt to repair the cold water in residential applications. product. All repairs must be per-...
1.4 Usage limits 1.5.1 Dimensions The product may only be used in accord- ance with the corresponding limits of use (see "Technical specifications"). 1.5 Structure inches G 3/4 B - G Thread inches G 1 B 80 / 110 / 115 115 / 130 / 120 / 130 11,7...
1.6 Identification 1.7 Display The ElecTo SJ meter has its identification data marked on it. 2022 ELECTO SJ 1383 M 22 2212345678 The display is a passive LCD. The display is set in fixed mode with the fol- lowing automatic display cycle: –...
See table "Error codes". 1.7.2 Periodic readings 1.8 Alarms Following an automatic sequence, billing ElecTo SJ is able to detect, store, and trans- date references are displayed: mit the following alarms via radio: – Billing date 1: displays the date for 3 –...
1.9 Technical specifications Description DN 15 DN 20 U.M. Accuracy class Maximum reading 99999.999 Maximum work- ing pressure T30: from +0.1 to +30 Temperature T50: from +0.1 to +50 °C classes T30/90: from +30 to +90 Sensitivity class for installation U0-D0 conditions Protection class...
1.11 Technical specifications for electronic timing device Features Description Environmental class Mechanical class Electronic class Temperature range for storage from -10 °C to +60 °C Ambient temperature range from -25 °C to +55 °C 1.12 Radio technical specifications Features Description Standard Wireless M-Bus (EN13757), OMS Modes...
Installation 2.2 Assembly Authorised personnel: specialised installer or plumber, assigned by the metering oper- 2.1 Receipt of the product ator. WARNING! Only authorised and suitably trained personnel with sufficient technical experience may install and operate the device. Before installing the device, make sure that the two sections of tube are even to prevent mechanical stress, clean them with care (es- pecially in the case of empty tubes) and let...
Page 12
Install the meter: – protected from frost (insulate it if necessary with insulation material) and in the lower part of the system to prevent air accumulation; – protected from blows and tampering, where readings are easy to make; – so that the direction of the arrow on the device coincides with the flow direction. Install proper interception valves upstream and downstream of the meter to permit main- tenance operations and inspections on the device, as well as to check the system.
Page 13
Installation position Observe the indications on the dial (letters H and V): – H: the meter must be installed with the dial in a horizontal position; – V: the meter must be installed with the dial in a vertical position; –...
10 litres of water. Programming mode is activated by tapping the magnetic key symbol with the magnetic key. ElecTo SJ is ideal for both cold and hot wa- The cumulative time for this mode is 120 ter residential use where compactness, flex- minutes.
Error codes Test mode The error code is displayed in hexadecimal ElecTo SJ can be temporarily set to a high format. resolution in order to carry out measure- The instrument identifies 4 errors which ment tests. may also occur simultaneously.
Maintenance 8.2 Cleaning No particular cleaning procedures are re- quired. However, the installation area 8.1 Battery (default) should be kept clean and periodic checks The meter is fitted with a 3.6V manganese should be performed to ensure the required lithium battery that cannot be recharged or environmental conditions are met.
Single Jet water meter with integrated radio Costruttore Maddalena S.p.A. Via G.B. Maddalena 2/4- 33040 Povoletto (UD), ltaly Manufacturer La presente dichiarazione di conformità è emessa sotto la responsabilità esclusiva del fabbricante. This declaration of conformity is issued under the sole responsibility of the manufacturer.
Page 18
® � maddalena iV'.ETER NG EXPERTISE Nome e numero dell'organismo Certificato nr. Attività notificato Activity Certificate no. Nome and number of the notijied body Certificato di esame UE del tipo in accordo al Czech Metrology lnstitute, NB 1383 Modulo B della Direttiva 2014/32/UE...
Page 20
Tel. +39 0432 634811 www.maddalena.it Maddalena S.p.A. reserves the right to change its products at any time and without prior notice, with the aim of improving them and without compromising primary features. All the graphic illustrations and/or photographs appearing in this document can be represented with optional accessories that vary in relation to the country where the device is used.
Need help?
Do you have a question about the ElecTo SJ and is the answer not in the manual?
Questions and answers