Chapter IX describes the configuration of the upper computer

The following figure shows the display interface for configuring the upper computer on the E610-433T30S.
Users can switch to the command mode by using M0 and M1 to quickly configure and read parameters on the upper
computer.
In configuring the upper computer, the module address, frequency channel, network ID and key are displayed
in decimal mode. The value ranges of each parameter:
Network address:0~65535
Frequency channel:0~83
Network ID:0~255
key:0~65535
When configuring the trunk mode on the upper computer, you need to pay special attention to the fact that
the parameters on the upper computer are displayed in decimal mode, so the module address and network ID
need to be converted into decimal;
If the network ID entered by transmitter A is 02 and the network ID entered by receiver B is 10, the hexadecimal
value 0X020A is converted to the decimal value 522 as the module address entered by relay R when setting
the module address;
In this case, the module address to be entered by the trunk R is 522。