    9.3 BER(B ............................... 14 RROR IS HIGH 10 PRODUCTION GUIDANCE ........................14 11 E62 SERIES ..............................15 12 ANTENNA RECOMMENDATION ......................15 13.PACKAGE FOR BATCH ORDER ......................16 REVISION HISTORY ............................. 17 ABOUT US ................................ 17 Chengdu Ebyte Electronic Technology Co,;Ltd...
  • Page 3: Overview

    Chengdu Ebyte Electronic Technology Co,;Ltd E62-433T30D user manual 1. Overview 1.1 Introduction E62-433T30D is a full-duplex wireless transceiver module with TTL level output, operates at 425-450MHz (default: 433MHz), transparent transmission available. Module features FHSS (Frequency-Hopping Spread Spectrum). During the transmitting...
  • Page 4: Specification And Parameter

    Chengdu Ebyte Electronic Technology Co,;Ltd E62-433T30D user manual Health care products;  Advanced Meter Reading Architecture(AMI);  Automotive industry applications.  2. Specification and parameter 2.1 2.1 Limit parameter Main parameter Performance Remarks Min. Max. Power supply(V) Voltage over 5.5V will cause permanent damage to module Blocking power(dBm)...
  • Page 5: Size And Pin Definition

    Chengdu Ebyte Electronic Technology Co,;Ltd E62-433T30D user manual antenna height: 2.5m,air data rate: 64kbps TX length 1024 Byte Internal automatic time division logic subcontracting Buffer 2048 Byte Internal Buffer Modulation GFSK Communication interface UART Package Connector 2.54mm Size 37*60mm Antenna...
  • Page 6: Connect To Mcu

    Chengdu Ebyte Electronic Technology Co,;Ltd E62-433T30D user manual Input Work with M1 to decide 2 working modes of module (not suspended, if (weak pull-up) not used, could be grounded). Module synchronization indication: high level indicates that both sides of communication have been synchronized, and data transmission can be...
  • Page 7: Function Description

    Chengdu Ebyte Electronic Technology Co,;Ltd E62-433T30D user manual For some MCU works at 5VDC, it may need to add 4-10K pull-up resistor for the TXD & AUX pin. 5 Function description 5.1 Reset When the module is powered, AUX outputs low level immediately, conducts hardware self-check and sets the operating mode based on user’s parameters.
  • Page 8: Notes For Aux

    Chengdu Ebyte Electronic Technology Co,;Ltd E62-433T30D user manual 5.2.3 Notes for AUX Description For function 1 & function 2 mentioned above, the priority should be given to the one with low level output, which means if it meets each of any low level output condition, AUX outputs low level, if none of the low level condition is met, AUX outputs high level.
  • Page 9: Transmission Mode (Mode 0)

    Chengdu Ebyte Electronic Technology Co,;Ltd E62-433T30D user manual 6.1 Mode switch Remarks The user can decide the operating mode by the combination of M1 and M0. The two GPIO of MCU can be used to switch mode. After modifying M1 or M0, it will start to work in new mode 1 ms later if the module is free. If there are any serial data that are yet to finish wireless transmitting, it will start to work in new mode after the UART transmitting finished.
  • Page 10: Configure Mode (Mode 1)

    Chengdu Ebyte Electronic Technology Co,;Ltd E62-433T30D user manual 6.3Configure mode (Mode 1) Type When M0 = 1, module works in mode 1. Transmitting N/A. User can configure the module at baud rate = 9600bps, parity = 8N1. Receiving N/A. User can configure the module at baud rate = 9600bps, parity = 8N1.
  • Page 11: Reading Version Number

    User gives the module instruction (HEX format): C3 C3 C3, C3+C3+C3 Module returns its present version number, for example C3 62 xx yy. 62 here means the module model (E62 series); xx is the version number and yy refers to the other module features. 7.4 Reset instruction...
  • Page 12 Chengdu Ebyte Electronic Technology Co,;Ltd E62-433T30D user manual FHSS The quantity of frequency hopping channel Both sides must keep the same. The  nums (default 0AH) more quantity of frequency-hopping channel, the better anti-interference while synchronization time is longer for both sides. Otherwise the less...
  • Page 13 Chengdu Ebyte Electronic Technology Co,;Ltd E62-433T30D user manual CHAN Communication frequency 00H- 33H,for 425 – 450.5MHz  (425M+CHAN*0.5M) When the frequency-hopping quantity  default 0AH sets as 1, the module works only at the fixed frequency (425M + CHAN * 0.5M).
  • Page 14: Hardware Design

    Chengdu Ebyte Electronic Technology Co,;Ltd E62-433T30D user manual For example: The meaning of No.3 "SPED" byte: The binary bit of the byte The specific value (user configures) UART parity bit Meaning UART baud rate is 9600 Air data rate is 64k Corresponding hexadecimal 8.
  • Page 15: Faq

    Chengdu Ebyte Electronic Technology Co,;Ltd E62-433T30D user manual weakened. 9 FAQ 9.1 Communication range is too short The communication distance will be affected when obstacle exists.  Data lose rate will be affected by temperature, humidity and co-channel interference. ...
  • Page 16: E62 Series

    Chengdu Ebyte Electronic Technology Co,;Ltd E62-433T30D user manual 11 E62 Series Frequenc Tx power Distance Size Model No. Core IC Data Rate Package Interface E62-433T20S 433M 16k~128k 17 * 30 IPEX/external/spring E62-433T30D 433M 16k~128k 37 * 60 SMA-K E62-433T20D 433M...
  • Page 17: Package For Batch Order

    Chengdu Ebyte Electronic Technology Co,;Ltd E62-433T30D user manual 13.Package for batch order Chengdu Ebyte Electronic Technology Co,;Ltd Copyright ©2012–2019,...
  • Page 18: Revision History

    About us Technical support: support@cdebyte.com Documents and RF Setting download link: www.ebyte.com Thank you for using Ebyte products! Please contact us with any questions or suggestions: info@cdebyte.com ------------------------------------------------------------------------------------------------------------ Fax: 028-64146160 ext. 821 Web: www.ebyte.com Address: Innovation Center D347, 4# XI-XIN Road,Chengdu, Sichuan, China Chengdu Ebyte Electronic Technology Co,;Ltd...