5.6.5 Module mode switching process

The M0 and M1 hardware mode switching process is used:
1、The external interrupt of pins M0 and M1 is triggered;
2、AUX pull down the pin;
3、Exit the current task mode and read the pin level of M0 and M1 to judge the new mode;
4、
Enter the new mode task, pull up AUX, and complete mode switching (switching time is about 40ms).

5.6.6 Notes

Number
For function 1 and function 2 above, the output low level is preferred, that is, if any
1
output low level condition is met, AUX will output low level;
AUX outputs a high level when all low level conditions are not met.
When AUX output low power level, it indicates that the module is busy and the working mode
2
detection is not performed.
Mode switching will be completed within 1ms after AUX output high level.
After the user switches to the new working mode, the module will not enter the mode until
3
at least 2ms after AUX rises.
If AUX is always on high, then the mode switch takes effect immediately.
When the user goes from mode 3 (sleep mode) to another mode or during reset, the module
4
will reset the user parameters, during which AUX output is low.