②Secondary trunking
The ADDH\ADDL of relay 2 is 33, 05, respectively.
So Trunk 2 can forward data from Trunk 1 to network NETID: 05.
Thus, node 3 and node 4 can receive node 1 data. Node 4 outputs data normally and node 3 has a different address from node 1, so it
does not output data.
③Two-way relay
As configured in the figure: the data sent by node 1 can be received by nodes 2 and 4, and the data sent by nodes 2 and 4 can be
received by node 1.
9 Host Computer Configuration Instructions
The following figure shows the display interface of the E22-230T22S configuration upper computer. Users can switch to
command mode through M0 and M1 for quick configuration and reading of parameters at the upper computer.
In the configuration upper computer, the module address, frequency channel, network ID, and key are displayed in decimal mode;