P0008961
With preheating
1 Press the ON/OFF button (6).
2 Press the SEL button (7) to come to the main
menu.
3 Navigate to Preheat with the browse button (9).
Press the SEL button (7)
4 In the Preheat menu, press the SEL button (7)
to select pre-heating; the text "Preheat active
please wait" is shown in the display.
5 Wait until the text disappears and then press the
START button (2).
47711097 09-2018 © AB VOLVO PENTA

Starting the Engine

DCU (Display Control Unit)

The pre-heating time is adjusted to suit engine
temperature, and may last up to 50 seconds both
before and after starting.
The starter motor connection time is maximized to 20
seconds. After that, the starter motor circuit is cut for
80 seconds to protect the starter motor against
overheating.
NOTICE! Preheat must be activated when the
temperature is below 0 °C (32 °F)
2
Without pre-heating
1 Press the ON/OFF button (6).
2 Press the START button (2).
Warm through the engine at idle (1,500/1,800 rpm).