Thermostat Confi guration
Confi guring the Equipment Settings
Enter the equipment code by changing the digits on the screen. Use the table below
to determine the correct equipment codes based on your specifi c HVAC unit.
Press the FAN button to advance to the next equipment setting.
Press the UP and DOWN buttons to increase or decrease the value;
Press the F|C button to advance to the next menu.
Setting #1
Digit
Compressor Type
0
No Compressor
1
Heat Pump
2
Air Conditioner*
3
*Indicates default setting.
18
Setting #2
Electric Heat
O/B Contact is energized
No Electric Heat
O/B Contact is energized
Electic Heat*
N/A
N/A
Setting #3
Reversing Valve
to cool
to heat*
N/A
Setting #4
Fan Speed
N/A
One Fan Speed
Two Fan Speeds*
Three Fan Speeds