Table 3-1. Recommended permissible misalignments.
Coupling information
Coupling
diameter
100-250 mm
(4-10")
250-500 mm
(10-20")
3.3 Final inspection of installation
3.3.1 Covers and enclosures
After the machine has been erected and aligned, check carefully that no tools or
foreign objects have been left inside the enclosures. Clean also any dust or debris.
When installing the covers, check that all sealing strips are intact before mounting
them.
Store alignment and assembly accessories and transport locking devices for future
use.
permissible misalignments shown in Table 3-1. Recommended
permissible misalignments
Coupling type
Rigid flange
Gear
Flexible
Rigid flange
Gear
Flexible
Page 27
Permissible misalignment
U
0,02 mm
0,01 mm
(0,8 mil)
(0,4 mil)
0,05 mm
0,03 mm
(2,0 mil)
(1,0 mil)
0,10 mm
0,05 mm
(4,0 mil)
(2,0 mil)
0,02 mm
0,01 mm
(0,8 mil)
(0,4 mil)
0,05 mm
0,03 mm
(2,0 mil)
(1,0 mil)
0,10 mm
0,05 mm
(4,0 mil)
(2,0 mil)
E
D
0,02 mm
(0,8 mil)
0,05 mm
(2,0 mil)
0,10 mm
(4,0 mil)
0,02 mm
(0,8 mil)
0,05 mm
(2,0 mil)
0,10 mm
(4,0 mil)