3.7 Venting the Appliance
For detailed instructions on venting the
appliance, see the relevant section in the
boiler installation manual (supplied).
The GF150 is heated by a TRX150C combi boiler,
itself a CSA-certified heating appliance.
As such, any GF150 installation must abide by
any applicable directions in the TRX150C boiler
installation manual (supplied).
In particular, the instructions pertaining to
venting the appliance (Part 5) are applicable
in their entirety.
Please review this section before proceeding
with the installation.
3.8 Connecting the Gas Supply
WARNING
Before connecting the gas supply, determine
●
the gas type and pressure for the appliance
by referring to the rating plate. Use only
the same gas type indicated on the rating
plate. Using a different gas type will result in
abnormal combustion and malfunction of the
appliance. Gas supplies should be connected
by a licensed professional only.
The appliance and its gas connection must be
●
leak tested before placing it in operation.
This appliance cannot be converted from
●
natural gas to propane or vice versa without
a gas conversion kit. Do not attempt a
field conversion of this appliance without
a gas conversion kit. Doing so will result in
dangerous operating conditions and will void
the warranty.
For gas conversion instructions, refer to
●
relevant sections of the boiler installation
manual (supplied).
Gas meter's capacity ≥ Total gas
capacity of connected appliances
Gas Supply Line
24
It is recommended that
this appliance be the first
connected to the gas supply
line.
* Gas connection can be made
on the left or right side of the
cabinet.