Advertisement

Example:
5
1
2
3
Pos. Description
1
Isolating valve, accessory
2
Dowels and screws
3
Pump
4
Non-return valve, accessory
5
Breeches pipe, accessory
6
Isolating valve, accessory
7
Vent hose
8
Vent flange
Related information
4.2.3 Connecting the outlet pipe
7
8
6
4
4.2.2 Connecting the inlet pipe
All pipe connections must be flexible to reduce
resonance.
Install an isolating valve in the inlet pipe.
Many installations require an inlet below the standard
inlet 700 mm above the floor. You can fit a lip seal on
site. Use the following accessories:
Product number
91713755
91712026
91071939
Do not stand on the lifting station.
Make sure that the weight from the inlet,
outlet and vent pipes does not rest on the
tank. Long pipe sections and valves must
be supported.
The internal diameter of the inlet pipe must be the
same as the internal diameter of the inlet port.
1. Cut open one of the inlet ports to be used and/or
connect pipes to the second tank.
2. Fit the DN 150 socket seal in the inlet port or the
optional DN 160 socket if the bottom inlet is
chosen.
3. Insert the inlet pipe into the socket seal.
To facilitate maintenance and service of the
product, we recommend that you fit an isolating
valve between the inlet port and the inlet pipe.
Required size: DN 100 or DN 150.
Related information
3.2 Scope of delivery
Description
Hole saw, ∅177
Centring drill
Lip seal, DN 150, internal
∅160