Electrolux SkyLine ChillS 202 User Manual page 49

Lengthwise blast chillers/freezers
Table of Contents

Advertisement

TYPE OF
CODE
ANOMALY
ALARM
Stops food
Eprb5
probe cycles
only if the entire
sensor is faulty
ALARM
Stops food
Eprb6
probe cycles
only if the entire
sensor is faulty
ALARM
B4
Stops machine
Ertc
WARNING
ECHt
WARNING
ALARM
E11
Stops machine
ERROR
B2
Stops cycle
DESCRIPTION
POSSIBLE CAUSES
• Food probe misuse (for example,
wire pulled or squeezed)
Core probe failure
• Connector failure
sensor n°5
• Probe failure
• PCB failure
• Food probe misuse (for example,
wire pulled or squeezed)
Core probe failure
• Connector failure
sensor n° 6
• Probe failure
• PCB failure
• Power supply missing
Supply power
• Supply power system failure
missing
• Other electrical issues (for exam-
ple current dispersions)
• Battery of User interface is low
Low battery
• Electronic board failure
• Door left open
Cavity high
• Food too hot in the cavity
temperature
• Issue with parameter ady or with
temperature measurement
• Fan condenser overload (exam-
ple: room temperature too high)
Compressor
• Electrical issue (example: con-
failure
nector unplugget)
• Gas leak
• Compressor damaged
• The door remained open beyond
the time limit set whit the active
Door open
cycle
• Door closure recognition system
is failed
ACTIONS
• Current running cycle:
a) the cycle continues in probe mode
until at least one out of the 6 food
probe points is working.
b) the cycle switches to time mode if
none out of the 6 food probe points is
working.
• During STANDBY:
a) the cycle can be started until at
least one point is working.
b) the cycle can be started in time
mode in case all points are failed.
• To restore full functionality, call
Service.
• Current running cycle:
a) the cycle continues in probe mode
until at least one out of the 6 food
probe points is working.
b) the cycle switches to time mode if
none out of the 6 food probe points is
working.
• During STANDBY:
a) the cycle can be started until at
least one point is working.
b) the cycle can be started in time
mode in case all points are failed.
• To restore full functionality, call
Service.
• Current running cycle: the cycle
restarts automatically when the
power is back.
• The machine was not in operation for
a certain period of time: check initial
and end time.
• Check the plug or general electric
control panel.
• If the alarm reoccurs, Call Service.
Problem with battery of internal clock.
Functions related to the clock will not
operate (example: HACCP event
recording will be wrong).
CALL SERVICE
• The cavity temperature has
exceeded the set limit, in additional
to the signal delay time.
• Current running cycle: the cycle
continues.
• If the alarm persists even if the cavity
temperature is low, call service.
• The chiller will be blocked and only
fan condenser runs.
• Check if there is any obstruction at
the suction air condenser.
CALL SERVICE
• Ensure the chiller door is closed and
any physical obstruction is not pre-
venting the door closure.
• Start new cycle: if either a new cycle
will not start or the alarm persists
even with the door closed, Call
Service.
49