Electrolux SkyLine ChillS 202 User Manual page 47

Lengthwise blast chillers/freezers
Table of Contents

Advertisement

TYPE OF
CODE
ANOMALY
ALARM
Stops Machine
in 6GN 1/1
EFnt
models.
Reducing Per-
formance on
other models
ALARM
Reducing per-
EFnb
formance until
another fan is
working
ALARM
Reducing per-
EFnc
formance until
another fan is
working
E1
WARNING
ALARM
E3
Stops machine
E4
WARNING
E14
WARNING
ALARM
E15
Stops Machine
DESCRIPTION
POSSIBLE CAUSES
• Parameter wrong setting
Top evaporator
• Fan connector wrongly plugged
fan failure
• Fan failure
• Parameter wrong setting
Bottom evapora-
• Fan connector wrongly plugged
tor fan failure.
• Fan failure
Center evapora-
• Fan connector wrongly plugged
tor fan failure
• Fan failure
Cavity low tem-
• Delay time set too short
perature (only
during holding
• Delta temperature set too narrow
cycles: positive or
• Evaporator icing
negative)
• Connector unplugged
Cavity probe
• Probe and/or Probe wire
failure
damaged
• Connector unplugged
Evaporator probe
• Probe and/or probe wire
failure
damaged
• Connector unplugged
Out Evaporator
• Probe and/or probe wire
probe failure
damaged
• Connector unplugged
Condenser probe
• Probe and/or probe wire
failure
damaged
ACTIONS
• CALL SERVICE
• 6GN 1/1 models (1 evaporator fan):
unit stops and cannot operate until
fixing the problem
• Other models (more than 1 evapora-
tor fan): unit continues working with
reduced performance (Cycle
ongoing: the cycle proceeds until end
if there is at least one fan working.
The cycle stops if no fan is working).
• During STANDBY: the alarm cannot
be triggered.
• CALL SERVICE
• Unit continues working with reduced
performance until at least another
fan is working (Cycle ongoing: the
cycle proceeds until end if there is at
least one fan working. The cycle
stops if no fan is working).
• During STANDBY: the alarm cannot
be triggered.
• CALL SERVICE
• Unit continues working with reduced
performance until at least another
fan is working (Cycle ongoing: the
cycle proceeds until end if there is at
least one fan working. The cycle
stops if no fan is working).
• During STANDBY: the alarm cannot
be triggered.
• The cavity temperature is below the
holding cycle temperature set point
for more than the set time (default
time = 1hour). The cycle will continue
until stopping.
Open the door for increasing the
temperature inside the cavity: check
it after a couple of minutes.
Launch a manual defrost cycle.
• Call service if the problem reoccurs.
• The chiller will continue working until
the end of the running cycle. Not
possible to start other cycle till to
Technical Service replace the probe.
• CALL SERVICE
• The chiller will continue working: the
defrost setting will be based on time.
• Call Service and inform about the
message displayed.
• The chiller will continue working.
• Call service and inform about the
message displayed.
• CALL SERVICE
• This failure blocks also running cycle.
• Quickly remove the load from the
cavity for preventing waste of food.
47