4.3 Final Set-Up and Test

To test the set-up and ensure that the frequency converter is running, follow these steps.
Step 1. Locate the motor name plate
Step 2. Enter the motor name plate data in this parameter list.
4
To access this list first press the [QUICK MENU] key then select "Q2 Quick
Setup".
1.
Motor Power [kW]
or Motor Power [HP]
2.
Motor Voltage
3.
Motor Frequency
4.
Motor Current
5.
Motor Nominal Speed
Step 3. Activate the Auto Tune
Performing an auto tune will ensure optimum performance. The auto tune measures the values from the motor model equivalent diagram.
1.
Activate the auto tune par. P-04 Auto Tune.
2.
Choose between complete or reduced auto tune. If an LC filter is mounted, run only the reduced auto tune, or remove the LC filter during the auto tune
procedure.
3.
Press the [OK] key. The display shows "Press [Hand] to start".
4.
Press the [Hand] key. A progress bar indicates if the auto tune is in progress.
82
NB!
The motor is either star- (Y) or delta- connected (∆). This information is lo-
cated on the motor name plate data.
par. P-07 Motor Power [kW]
par. P-02 Motor Power [HP]
par. F-05 Motor Rated Volt-
age
par. F-04 Base Frequency
par. P-03 Motor Current
par. P-06 Base Speed