3-20
I
O
NSTALLING AND
CB5000> monitor 00:10 ethernet ethernet_1
Ethernet Statistics for ETHERNET_1
-----------------------------------------------------------
-----------------------------------------------------------
FCS Errors
SQE Test Errors
Alignment Errors
Carrier Sense Errors
Frame Too Longs
Deferred Transmissions
Late Collisions
Excessive Collisions
Single Collision Frames
Multiple Collision Frames
Internal MAC Receive Errors
Internal MAC Transmit Errors 0
Display will refresh every 10 seconds.
Press CTRL-C to exit.
M
PERATING THE
ODULE

Monitor Command

The MONITOR command enables users to monitor each network
(individually) by specifying the backplane segment to which your ports
are configured. Use the following syntax to implement the command:
MONITOR {mm:ss}
The system-specified range of time allotted for monitoring the network
is 00 to 30 (minutes) and 05 to 59 (seconds). Use these values when
specifying a length of time to monitor your network.
The following output is an example of the MONITOR ETHERNET
command for a 24-Port module installed in slot 10. This example
monitors ethernet_1 every 10 seconds:
{ETHERNET} {ethernet_1..._8}