Selectiva 18 Kw 400 V - Fronius Selectiva 4.0 8 - 18 kW Operating Instructions Manual

Table of Contents

Advertisement

Selectiva 18 kW
400 V
Danger of electric shock due to a residual current can be fatal.
Only use a type B residual current circuit breaker for the mains connection of the
device.
Mains voltage (-10%/+30%)
Optional:
Mains fuse
Selectiva 2250/2300/2350
Selectiva 4250/4300/4325
Minimum cross-section of the mains lead
Selectiva 2250/2300 / 2350
Selectiva 4250/4300/4325
Duty cycle
EMC emission class
Standby consumption
Selectiva 2250/2300/2350
Selectiva 4250
Selectiva 4300/4325
Safety class
Max. permitted grid impedance Z
PCC
Protection class
Overvoltage category
Operating temperature
Storage temperature
Relative humidity
Maximum altitude above sea level
Mark of conformity
Product standard
Dimensions L x W x H
Weight (with standard grid and charging
cable)
Pollution degree
1)
2)
70
WARNING!
2)
4)
5)
6)
The device may be operated on grids that are grounded at the neutral
point with a maximum outer conductor nominal voltage of 400 V. A mains
voltage tolerance L-N of 207 V to 250 V applies to the electrolyte circula-
tion and relay board options.
Only use a type B residual current circuit breaker for the mains connec-
tion of the device. The leakage current to earth is less than 3.5 mA.
3~ NPE 400 V / 50/60 Hz
1
)
3~ PE 400 V / 50/60 Hz
16 A/32 A
32 A
4 mm² (0.0062 in.²)
6 mm² (0.0093 in.²)
100%
B
12.6 W
12.7 W
13.1 W
I
on
According to the "Device-spe-
max
cific data" table below
Protection class 20
III
-20°C to +40°C
(-4°F to 104°F)
-25°C to +80°C
(-13°F to 176°F)
max. 85%
2000 m (6561 ft)
According to rating plate
EN 62477-1
785 x 247 x 392 mm
(30.91 x 9.72 x 15.43 in)
47 kg (103.62 lbs.)
3
3)

Advertisement

Table of Contents
loading

Table of Contents