Technical data

Selectiva 2 kW

Mains voltage
Mains frequency
Mains fuse
Minimum cross-section of the grid lead
Safety class
Max. permitted grid impedance Z
PCC
Standby consumption
EMC device class
Dimensions l x w x h
Pollution degree
Degree of protection
Overvoltage category
Operating temperature
Storage temperature
Relative humidity
Maximum altitude above sea level
Mark of conformity
Product standard
1)
2)
3)
4)
5)
Device-specific
data
2040 2kW
2050 2kW
2060 2kW
1)
2)
3)
4)
5)
The device may be operated on grids that are grounded at the neutral
point.
The thermal rating of the automatic circuit breaker must not exceed
2
30,000 A
s.
The leakage current to earth is less than 3.5 mA.
Interface to a 230/400 V and 50 Hz public grid.
For indoor use only, must not be exposed to rain or snow.
At a high ambient temperature, a power reduction may occur (derating).
Max. AC
current
7.9 A
9.9 A
12.0 A
~ 230 V, ± 15%
50/60 Hz
max. 16 A
1.5 mm² (0.002325 in.²)
I (with ground conductor)
on
None
max
4.9 W
B
341 x 110 x 198 mm
(13.43 in. x 4.33 x 7.8 in.)
3
IP21
II
-20°C to +40°C
(-4°F to 104°F)
-25°C to +80°C
(-13°F to 176°F)
max. 85%
2000 m (6561 ft.)
According to rating plate
EN62477-1
Max. AC
Nominal
power
voltage
1540 W
24 V
1930 W
24 V
2330 W
24 V
Max.
charging
6)
current
Weight
40 A
5.8 kg
(12.79 lb.)
50 A
6.1 kg
(13.45 lb.)
60 A
6.1 kg
(13.45 lb.)