Replacing The Data Cable; Procedure - Precor Energy Series Service Manual

Hide thumbs Also See for Energy Series:
Table of Contents

Advertisement

Replacing the Data Cable

Procedure

1. Set the treadmill on/off switch in the "off" position and remove the treadmill power cord from
the AC outlet.
2. Remove the treadmill hood.
3. Remove the four screws that fasten the console to the backplate.
4. Disconnect the data cable from the JK8 connector on the console.
5. Tie a seven to eight foot long piece of string to the lower end of the data cable.
6. Pull the data cable out of the upper end of the targa upright. Stop when the string is projecting
out of the upper and lower ends of the targa upright. Remove the data cable from the string
and discard the data cable.
7. Tie the lower end of the string onto the replacement data cable. Carefully draw the string out of
the top of the targa upright while feeding the data cable into the lower end of the targa upright.
Stop when the data cable is projecting out of the upper and lower ends of the targa upright.
Untie the string from the data cable.
8. Connect the data cable to the JK8 connector on the console and the JK1 connector on the
lower PCA.
9. Install the console in its mounting position on the backplate and fasten with the attachment
hardware.
10. Replace the treadmill hood.
11. Verify the treadmill operation.