Tenda TES70 Series Quick Installation Manual
Hide thumbs Also See for TES70 Series:

Advertisement

Quick Links

Document version: V1.0
1

Advertisement

Table of Contents
loading

Summary of Contents for Tenda TES70 Series

  • Page 1 Document version: V1.0...
  • Page 2 Tenda does not assume any liability that may occur due to the use or application of the product described herein. Every effort has been made in the preparation of this document to ensure accuracy of the contents, but all statements, information and recommendations in this document do not constitute a warranty of any kind, express or implied.
  • Page 3 Preface Thank you for choosing Tenda! This guide walks you through the pre-installation preparation and hardware installation on the TES70 series GPON OLT. All the figures herein are only for illustration. Refer to the actual conditions. Application scope The application scope of this guide is listed as below.
  • Page 4 Contact us if you need more help. We will be glad to assist you as soon as possible. Email address: support@tenda.cn Website: www.tendacn.com Revision history Tenda is constantly searching for ways to improve its products and documentation. The following table indicates any changes that might have been made since the guide was released. Version Date Description V1.0...
  • Page 5: Table Of Contents

    Document version: V1.0 Contents Device appearance ......................1 1.1 Front panel ..........................1 1.2 Back panel ..........................4 Hardware installation ......................5 2.1 Open box and checkout ......................5 2.2 Installation requirements ......................6 2.2.1 Power requirements ....................... 6 2.2.2 Device grounding requirements ..................6 2.2.3 Installation site requirements ..................
  • Page 6 Document version: V1.0 3.2 OLT console parameter configuration ................... 13 3.3 OLT default username and password..................13...
  • Page 7: Device Appearance

    Document version: V1.0 Device appearance TES7004/TES7008/TES7016 are 1U standard Pizza-Box devices and can be mounted into a standard 19-inch rack. The length, width, height of the device is: 440 mm * 240 mm * 44 mm. Front panel TES7004 front panel appearance TES7008 front panel appearance TES7016 front panel appearance...
  • Page 8 Document version: V1.0 OLT front panel ports description Device Model TES7004 TES7008 TES7016 Port Type Optional: 2 * 10-gigabit ports 2 * 10-gigabit ports + SFP Port 2 * 10-gigabit ports 2 * gigabit ports 2 * 10-gigabit ports + 2 * gigabit ports Uplink port...
  • Page 9 Document version: V1.0 LED status description Unless other specified, the corresponding descriptions are applicable to all TES70 series products. LED Indicator Type Status Description Solid green System running properly Slowly blinking System initializing, or software starting but master-slave green communication state is not established...
  • Page 10: Back Panel

    Document version: V1.0 LED Indicator Type Status Description TES7004 UPLINK Solid on Port connected XGE1/XGE2 TES7008 UPLINK Fast blinking Port transmitting or receiving data XGE1/XGE2 TES7016 UPLINK XGE1/XGE2, GE3/GE4 Port disconnected or connect improperly (Uplink port indicator) Indicates that port rate is 100 M. TES7004 UPLINK GE3/GE4 Yellow...
  • Page 11: Hardware Installation

    Document version: V1.0 Hardware installation Open box and checkout Check the products referring to the package contents or contract. If any item is missing, or damaged, please keep the original package and contact the local reseller or distributor immediately. The package contents include the following items: OLT device * 1 −...
  • Page 12: Installation Requirements

    Document version: V1.0 Installation requirements 2.2.1 Power requirements The input voltage must be stable with neither EMI noise nor distortion. When DC power supply is used, the input voltage is - 48 V DC and the allowed range is − - 40 V DC to - 72 V DC.
  • Page 13: Installations Preparations

    Document version: V1.0 Installations preparations 2.3.1 Safety precautions Check the following working environment and installation requirements: During installation, wear ESD wrist straps or gloves. And the OLT should be powered − off. Please use the included power adapter/power cord. − Ensure that the input voltage is within the input range indicated on the OLT.
  • Page 14: Olt Installation

    Document version: V1.0 OLT installation 2.4.1 Rack mounting (19 inch) Ensure that the rack is stable, level and properly grounded. Step 1 Fix the L-shaped brackets to both sides of the OLT with the included screws. Step 2 Place the OLT in an appropriate position in the rack. Fix the L-shaped brackets to the rack Step 3 with screws (self-prepared).
  • Page 15 Grounding cable connecting To ensure the safety and reliable working of OLT, proper ground connection should be performed for OLT. For detailed grounding methods, refer to Tenda Lightning Protection Guide. Power supply connecting Connect the power supply of the OLT based on your power supply selection and the corresponding power supply connection instructions.
  • Page 16 Document version: V1.0 the other power supply unit. To ensure true AC line input redundancy for the OLT, connect each AC power cable to a different AC power source. The procedure for connecting the AC power supply is as follows: Get the supplied AC power cords from the OLT's package contents.
  • Page 17: Olt Working Status Checkout

    Document version: V1.0 OLT working status checkout 2.5.1 Power supply checkout Before you connect the power supply, carefully check the power supply to see whether it is in line with the power supply requirements, and whether the device is in reliable grounding. After verification, you can turn on the power supply sources.
  • Page 18: Network Management Checkout

    Document version: V1.0 2.5.5 Network management checkout The management computer can manage the device in the following two ways. Local command line interface management: ◼ Use a DB9 or Type-C serial cable to connect the management computer to the Console management port of the OLT device, and then access the command line management interface of the OLT device through the serial port.
  • Page 19: Olt Default Configuration

    Document version: V1.0 OLT default configuration Network parameter configuration Default IP address of OLT outband management port: IP Address: 192.168.0.254 ◼ Subnet Mask: 255.255.255.0 ◼ OLT console parameter configuration Baud Rate: 115200 ◼ Data Bit: 8 ◼ Parity Check: NO ◼...

This manual is also suitable for:

Tes7004Tes7008Tes7016

Table of Contents