2.5

OLT working status checkout

2.5.1

Power supply checkout

Before you connect the power supply, carefully check the power supply to see whether it is in line
with the power supply requirements, and whether the device is in reliable grounding. After
verification, you can turn on the power supply sources.
2.5.2
OLT working status checkout
Please check the OLT's working status from the following aspects:
Check the PWR (power indicator). The indicator should be solid green.
Check the ACT (system status indicator). The indicator should be solid green.
If the uplink device is connected to the uplink port, the target connection indictor is
on.
2.5.3

ONT registration status checkout

By default, after the ONT device is started, it will be registered on the OLT without any
configuration.
You can prepare an ONT device for registration checkout.
Before connecting the device, it is recommended to use an optical power meter to test whether
the optical function is within the working range required by the device.
Then, connect the ONT device to the PON port of the OLT. The corresponding PON port indicator
should be on, and the ONT is registered successfully.
2.5.4

Network connection checkout

By default, after the ONT device is normally registered on the OLT, the network between the ONT
user and the device connected to the OLT should be connected.
The checkout procedures are as follows:
Connect a test computer to the user port of the ONT device.
Step 1
Use the PING package tool on the test computer to ping the IP address of the OLT uplink
Step 2
devices in the same LAN (same IP address segment).
Checkout result: The IP address of the OLT uplink devices can be pinged successfully on the test
computer.