Ethernet Ports (Eth0 And Eth1); Ethernet Connector; Connection Of Ethernet Cable; Ethernet Connector Pinout - Advantech SmartFlex SR309 User Manual

Lte industrial router
Hide thumbs Also See for SmartFlex SR309:
Table of Contents

Advertisement

5.9.6 Ethernet Ports (ETH0 and ETH1)

The panel socket RJ45 is used for this interface. The isolation barrier of the Ethernet signal
ports against the ground is 1500 V.
Pin
1
2
3
4
5
6
7
8
The crossover UTP cable (Ethernet cable) plugs into the RJ45 connector labeled as ETH0
or ETH1 (see the figure below).
The insulation strength of Ethernet ports from each other and from the rest of the router
(grounding) is dependent on the router version:
Router Version
Insul. Strength from Router
Without PoE
1.5 kV
PoE PD
1.5 kV
PoE PSE
none
10base-T & 100base-T
Tx+ (Transmit Data+)
Tx- (Transmit Data-)
Rx+ (Receive Data+)
Rx- (Receive Data-)
Table 9: Ethernet connector pinout
Figure 22: Ethernet connector
Figure 23: Connection of Ethernet cable
Table 10: Insulation strength of Ethernet ports
22
SmartFlex SR309
PoE (Mode B)
PoE + (positive pole)
PoE + (positive pole)
PoE - (negative pole)
PoE - (negative pole)
Insul. Strength between Ports
1.5 kV
none
none

Advertisement

Table of Contents
loading

Table of Contents