5.9.6 Ethernet Ports (ETH0 and ETH1)
The panel socket RJ45 is used for this interface. The isolation barrier of the Ethernet signal
ports against the ground is 1500 V.
The crossover UTP cable (Ethernet cable) plugs into the RJ45 connector labeled as ETH0
or ETH1 (see the figure below).
The insulation strength of Ethernet ports from each other and from the rest of the router
(grounding) is dependent on the router version:
Router Version
Without PoE
PoE PD
PoE PSE
LUCOM GmbH — Flößaustr. 22a — 90763 Fürth — Tel.: +49 911/ 957 606 00 — E-Mail: info@lucom.de — www.lucom.de
Pin
10base-T & 100base-T
1
Tx+ (Transmit Data+)
2
Tx- (Transmit Data-)
3
Rx+ (Receive Data+)
4
—
5
—
6
Rx- (Receive Data-)
7
—
8
—
Table 12: Ethernet connector pinout
Figure 32: Ethernet connector
Figure 33: Connection of Ethernet cable
Insul. Strength from Router
1.5 kV
1.5 kV
none
Table 13: Insulation strength of Ethernet ports
SmartFlex SR305
PoE (Mode B)
—
—
—
PoE + (positive pole)
PoE + (positive pole)
—
PoE - (negative pole)
PoE - (negative pole)
Insul. Strength between Ports
1.5 kV
none
none
26