5.8.5 Ethernet Ports (ETH0 and ETH1)

The panel socket RJ45 is used for this interface. The isolation barrier of the Ethernet signal
ports against the ground is 1500 V.
Pin
Signal mark
1
TXD+
2
TXD-
3
RXD+
4
DC+
5
DC+
6
RXD-
7
DC-
8
DC-
The crossover UTP cable (Ethernet cable) plugs into the RJ45 connector labeled as ETH0
or ETH1 (see the figure below).
The insulation strength of Ethernet ports from each other and from the rest of the router
(grounding) is dependent on the router version:
Router Version
Insul. Strength from Router
Without PoE
1.5 kV
PoE PD
1.5 kV
PoE PSE
none
Description
Transmit Data – positive pole
Transmit Data – negative pole
Receive Data – positive pole
PoE power + (if it's equipped by PoE)
PoE power + (if it's equipped by PoE)
Receive Data – negative pole
PoE power - (if it's equipped by PoE)
PoE power - (if it's equipped by PoE)
Table 12: Connection of Ethernet connector
Figure 15: Ethernet connector
Figure 16: Connection of Ethernet cable
Table 13: Insulation strength of Ethernet ports