Electrolux Professional CWC10B Installation Manual

Blast chillers/freezers

Advertisement

Quick Links

Blast Chillers/Freezers
Crosswise
EN
Installation manual *
595R 508 00- 2019.12
*Original instructions

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CWC10B and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Electrolux Professional CWC10B

  • Page 1 Blast Chillers/Freezers Crosswise Installation manual * 595R 508 00- 2019.12 *Original instructions...
  • Page 2 Installation diagram type CWC10B – CWF10B model 7–10kg GN 1/1...
  • Page 3 Installation diagram type CWC15B – CWF15B model 15kg GN 1/1...
  • Page 4 Installation diagram type CWC15R – CWF15R model 15kg GN 1/1 remote INLET EXT Ø6mm OUTLET EXT Ø12mm...
  • Page 5 Installation diagram type CWC28B – CWF28B model 28kg GN 1/1...
  • Page 6 Installation diagram type CWC28R – CWF28R model 28kg GN 1/1 remote OUTLET EXT Ø12mm INLET EXT Ø8mm...
  • Page 7 Installation diagram type CWC56VB – CWF56VB model 56–64kg GN 1/1...
  • Page 8 Installation diagram type CWC56HB – CWF56HB model 56–64kg GN 2/1 1000 1000...
  • Page 9 Installation diagram type CWC56VR – CWF56VR model 56–64kg GN 1/1 remote OUTLET INT Ø16,2mm INLET INT Ø10,4mm...
  • Page 10 TYPE = Certification group B = On board unit version CW= Crosswise range R= Remote unit version 10–15–28–56H-56V = Capacity EI = Power cable length H = Horizontal RI = Refrigerant inlet (liquid) - (remote models) V = Vertical RO = Refrigerant outlet (gas) - (remote models) C-F = Temperature range (C= Chiller / F= Freezer) D = Compartment drain hole...
  • Page 11 Foreword The installation, use and maintenance manual (hereinafter Manual) provides the user with information necessary for correct and safe use of the machine (or “appliance“). The following must not be considered a long and exacting list of warnings, but rather a set of instructions suitable for improving machine performance in every respect and, above all, preventing injury to persons and animals and damage to property due to im- proper operating procedures.
  • Page 12: Table Of Contents

    Contents A WARNING AND SAFETY INFORMATION....................13 General information ........................13 Personal protection equipment ...................... 14 General safety ........................... 14 Technical data..........................14 Transport, handling and storage ....................15 Installation and assembly ......................15 Machine disposal........................17 B APPLIANCE AND MANUFACTURER'S IDENTIFICATION DATA ..............17 C GENERAL INFORMATION ........................
  • Page 13: Awarning And Safety Information

    Read the instructions before using the appliance Clarifications and explanations Manufacturer Electrolux Professional SpA Viale Treviso 15 33170 Pordenone Italy www.electrolux.com/professional • These appliances are intended to be used for commercial applications, for example in kitchens of restaurant, canteens, hospitals and in commercial enterprises such as bakeries, butcheries, etc., but not for continuous mass production of food .
  • Page 14: Personal Protection Equipment

    Personal protection equipment Summary table of the Personal Protection Equipment (PPE) to be used during the various stages of the machine's service life. Stage Protective Safety Gloves Glasses Safety footwear helmet garments — ● ○ — ○ Transport ● ○ —...
  • Page 15: Transport, Handling And Storage

    Climatic Class The climatic class given on the data plate refers to the following values: • CLIMATIC CLASS: 4 – 32℃ (IEC/EN 60335-2-89) – 30℃ room with 55% relative humidity (IEC/EN ISO 23953). • CLIMATIC CLASS: 5 – 43℃ (IEC/EN 60335-2-89) –...
  • Page 16 • The machine that can operate at 50 or 60 Hz does not need any setting by the user. Electrical connection for appliances with plug (only for CWC10B – CWF10B – CWCF15B – CWC28B models) • To connect to the power supply, insert the power cable plug in the corresponding mains socket, first making sure: •...
  • Page 17: Machine Disposal

    Rated Pressure IP23 Refrigerant type of refrigerant gas Electrolux Professional SPA - Viale Treviso, 15 - 33170 Pordenone (Italy) Cap. nominal capacity IP23 dust and water protection rating The data plate gives the product identification and technical data.
  • Page 18: Cgeneral Information

    Given below is some information regarding the intended use of Manufacturer Electrolux Professional SpA or any other this appliance, its testing, and a description of the symbols service centre authorised by Electrolux used (that identifies the type of warning), the definitions of Professional SpA.
  • Page 19: Dtransport, Handling And Storage

    personal protection equipment to be worn by operators, in Any supplements to the installation, use and maintenance compliance with regulations in force in the country of use. manual the Customer receives from the Manufacturer will form an integral part of the manual and therefore must be kept The Manufacturer declines any liability for inaccuracies con- together with it.
  • Page 20: Main Technical Characteristics

    Main technical characteristics Power supply voltage V 230V/1ph1/50Hz 220–230V/1ph/50Hz 220–230V/3ph/60Hz 220–240V/1ph/50/60Hz 220–240V/1ph/50Hz 380–400V/3ph+N/60Hz 220–230V/1ph/60Hz 380–415V/3ph+N/50Hz 380–415V/3ph+N/50/60Hz 220–240V/3ph/50/60Hz Depending on the model Trays Gastronorm Trays GN1/1 Pastry Trays (325mm x 530mm – h 65mm) (400mm x 600mm – h 65mm) 7–10kg GN 1/1 15kg GN 1/1 28kg GN 1/1 56–64kg GN 1/1...
  • Page 21: Customer's Responsibilities

    steel surface has to be coated by a paraffin protective film spread by using a rag soaked with paraffin. The manufacturer declines any liability for corrosive effects due to external causes. Customer's responsibilities The tasks and works required to the Customer are: •...
  • Page 22: Draining Water

    Draining water The drain diameter is 1½″, therefore it is advisable to use a 1½″ drain pipe. • Manual draining : Emptying must occur through a trap into an open drain to The appliances have a drain hole, and when the plug is prevent any backflow from the drainage system reaching the removed any liquids in the compartment run into the tray internal pipes of the appliance.
  • Page 23: 56-64Kg Models

    56–64kg models • undo the screws fixing lower bracket “E” and hinge fixing screw “D”; These models are normally supplied with right door opening. • remove the door; To change to left opening, proceed as follows: • refit bottom hinge “E” on the opposite side of the cabinet •...