ISHIDA SR2000 Calibration Procedure
Hide thumbs Also See for SR2000:

Advertisement

CALIBRATION PROCEDURE FOR ISHIDA SR2000
1.
Remove weighing platter. Near the front left side of the scale
cover there will be 2 hexagon shaped screws. Locate the one on
the left side as this one accesses the memory initialization switch.
2.
Remove the left side hex screw with a 5/32" hex wrench.
3.
Re-install the weighing platter.
4.
Turn power on.
5.
Press the MENU button on the touch panel display
6.
Press 4 9 5 3 4 4 PLU and touch the TEST MODE button on the
touch panel. Press the calibration button.
7.
The following screen should appear in the display
8.
Make sure the scale is level and ensure there is nothing touching
the weighing platter. Press the ZERO button to set the zero
setting of the weight platter. Now place the full capacity span
weight on the weighing platter and press SPAN.
For span weight setting:
Metric
Imperial
15kg
30lbs

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SR2000 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for ISHIDA SR2000

  • Page 1 CALIBRATION PROCEDURE FOR ISHIDA SR2000 Remove weighing platter. Near the front left side of the scale cover there will be 2 hexagon shaped screws. Locate the one on the left side as this one accesses the memory initialization switch. Remove the left side hex screw with a 5/32” hex wrench.
  • Page 2 Remove the weight from the platter and remove the platter. Using a long thin instrument, insert into the hole where the hex screw was removed in steps 1&2, press until the switch is activated (make sure power is still on). 10.

Table of Contents