Installing the Device
2.1 General Procedure
This product should be installed in a restricted access location where access can only
be gained by authorized personnel who have been informed of the restrictions and
any precautions that must be taken. Access must only be possible through the use
of a tool, lock and key, or other means of security, and controlled by the authority
responsible for the location.
2.1

General Procedure

The general procedure for installing the device is as follows:
The user is responsible for the operating environment of the device, including
maintaining the integrity of all protective conductor connections and checking
equipment ratings. Make sure to review all operating and installation instructions
before commissioning or performing maintenance on the device.
1.
2.
3.
4.
5.
6.
2.2

Mounting the Device

The RUGGEDCOM RS8000H is designed for maximum mounting and display
flexibility. It can be equipped with connectors that allow it to be installed in a 48 cm
(19 in) rack, 35 mm (1.4 in) DIN rail, or directly on a panel.
Heat generated by the device is channeled outwards from the enclosure. As such, it
is recommended that 2.5 cm (1 in) of space be maintained on all open sides of the
device to allow for some convectional airflow.
Forced airflow is not required. However, any increase in airflow will result in a
reduction of ambient temperature and improve the long-term reliability of all
equipment mounted in the rack space.
8
NOTICE
NOTICE
Review the relevant certification information for any regulatory requirements.
For more information, refer to
Mount the device.
Connect the failsafe alarm relay.
Connect power to the device and ground the device to safety Earth.
Connect the device to the network.
Configure the device.
NOTICE
"Approvals" (Page
25).
Installation Manual, 11/2022, C79000-G8976-1022-07
RUGGEDCOM RS8000H