User Guide DVI Extenders DTP DVI 4K 230 D Series DVI Twisted Pair Extender Transmitters and Receivers 68-2365-01 Rev. C 05 17...
Page 2
Safety Instructions Safety Instructions • English Istruzioni di sicurezza • Italiano WARNING: This symbol, , when used on the product, is intended to AVVERTENZA: Il simbolo, , se usato sul prodotto, serve ad alert the user of the presence of uninsulated dangerous voltage within avvertire l’utente della presenza di tensione non isolata pericolosa the product’s enclosure that may present a risk of electric shock.
Contents Reference Information Introduction ....... 16 ........... 1 Decorator-Style Wallplate Template About this Guide ..........1 Dimensions ............. 16 About the DTP DVI 4K 230 D Extenders ..... 1 Twisted Pair Cable Advantages ....... 2 Transmission Distance ........2 Features ............. 2 Installation and Operation ......
Introduction • About this Guide About the DTP DVI 4K 230 D Extenders • • Features About this Guide This guide describes the Extron DTP DVI 4K 230 D family of Digital Visual Interface (DVI) Extenders, which consists of the DTP DVI 4K 230 D Tx and DTP DVI 4K 230 D Rx. This guide describes how to install, operate, and configure them.
Twisted Pair Cable Advantages Twisted pair cable is much smaller, lighter, more flexible, and less expensive than coaxial or DVI cable. These transmitter and receiver twisted pair (TP) products make cable runs simpler and less cumbersome. Termination of the cable with RJ-45 connectors is simple, quick, and economical.
Installation and Operation This section describes the installation and the operation of the DTP DVI 4K 230 D transmitter and receiver, including: • Mounting the Transmitter or Receiver • Transmitter Connections • Receiver Connections • Connector and Cable Details • Power Supply Wiring •...
Page 11
NOTE: The decorator-style wallplateunits are very deep and have connectors on the back side. Extron recommends a 2-gang junction box which has a depth of 3.0 inches (7.6 cm). To install a new wall box, perform steps 1 through 9. If a suitable wall box is already installed, perform steps 6 through 9 on the next page.
Feed the twisted pair cables and the power cables through the opening and through the wall box punch-out holes, securing them with cable clamps to provide strain relief. NOTES: • In order to fit in the junction box, the twisted pair cables and RJ-45 connectors should not have a boot installed.
Final Installation After testing and making any adjustments, do the following: At the power outlet, unplug the power supply. NOTE: One power supply can power both the transmitter and the receiver (see Power Supply Wiring on page 11 and Ground Loops on page 15).
Audio input — Connect an unbalanced stereo audio source to this 3.5 mm mini stereo jack for unbalanced audio input. Figure 5 shows how to wire the audio plug. Left (+) Ring Right (-) Sleeve ( ) Figure 5. Audio Input Connector Wiring RS-232 and IR (Control) pass-through connector —...
Connect the opposite end of the twisted pair cable to the receiver input port shown in figure 7 (see TP Cable Termination and Recommendations on page 10 to properly wire the RJ-45 connectors). NOTES: • In order to fit in the junction box, the twisted pair cables and RJ-45 connectors should not have a boot installed.
NOTES: • In order to fit in the junction box, the twisted pair cables and RJ-45 connectors should not have a boot installed. • Do not use Extron STP201 or Skew-Free UTP series cable with these products DC power input connector — Plug the included external 12 VDC power supply into either this 2-pole connector or the power input connector on the receiver (see Power Supply Wiring...
Connector and Cable Details TP Cable Termination and Recommendations Figure 9 details the recommended termination of both ends of TP cables with RJ-45 connectors in accordance with the TIA/EIA T 568B wiring standard. Pins: TIA/EIA T 12345678 568 B Wire color White-orange Orange White-green...
Power Supply Wiring NOTES: • Only one power supply is required. A single power supply connected to either unit in the pair powers both units (see Ground Loops on page 15). • A power supply is included with each individually-packaged transmitter. Figure 10 shows how to wire the connector.
Page 19
ATTENTION: • Always use a power supply supplied and or specified by Extron. Use of an unauthorized power supply voids all regulatory compliance certification and may cause damage to the supply and the end product. • Utilisez toujours une source d’alimentation fournie ou recommandée par Extron. L’utilisation d’une source d’alimentation non autorisée annule toute conformité...
RS-232 and IR Connector Wiring Figure shows how to wire the RS-232 and IR connector for the DTP DVI 4K 230 D units. Function RS-232 RS-232 Transmit data Receive data Tx Rx G Tx Rx Signal ground Tx Rx G Tx Rx Controlling Do not tin the wires!
Receiver Power Indicator Power LED — This two-color front panel LED lights to indicate signal and power status as follows: Amber — The unit is receiving power but no signal on the TP input. • Green — The unit is receiving power and a signal is present on the TP input. •...
Ground Loops When installing the DTP DVI 4K 230 D series products, be sure to avoid scenarios where the ground potential differs greatly between the locations where the DTP transmitter and DTP receiver are installed. Such situations can cause ground loops, which can result in image drops, no image, or damage to the units.
Reference Information This section includes decorator-style wallplate template dimensions for installation of the DTP DVI 230 D transmitters and receivers. Decorator-Style Wallplate Template Dimensions If you need to create a template, use the dimensions shown on figure 14. NOTES: • The drawing is not full size or to scale.
Page 24
Extron Electronics makes no further warranties either expressed or implied with respect to the product and its quality, performance, merchantability, or fitness for any particular use. In no event will Extron Electronics be liable for direct, indirect, or consequential damages resulting from any defect in this product even if Extron Electronics has been advised of such damage.