2.5 Installing the unit

1. Flush the cold water pipe thoroughly.
2. Fit a secure connection cable (10
ensure dimensions are correct).
3. Release cover securing screw (11).
4. Remove cover.
5. Determine the position of the drillholes
and drill the holes. Insert the wall plugs
and screw in the screws (ensure screw
insertion depth is correct, 12).
6. Feed the connection cable through the
cable seal (2) in the rear wall. Guide the
unit over the wall securing screws and
slide it downwards (13).
7. Fit the cold water connection.
Connect the water valve with the filter (14)
and the washer to the cold water inlet of the
unit (6). Tighten the water valve.
8. Straighten the unit and tighten the screws.
9. Connect the electrical supply.
10. Fit the cover and secure with the screw.
11. Turn the rotary control (A) to the left and
right (internal setting lever will engage).
12. Fit the shower accessories to the unit.
4. Fault elimination for the user
Fault
No hot water despite flow volume setting at
right-hand stop.
"Trip" - light on
The unit is not being switched on. Electricity
supply and flow available.
The outlet must not be connected to
any tab or fitting other than those
specified

2.6 First operation

(Only to be carried out by a qualified installer)
Before switching on, set the rotary
water valve to "Max" setting until the
pipework and the unit are free of air.
- Check the operation of the water heater.
- Before switching "ON" set the rotary
temperature to "OFF"
Handing over the unit
Explain to the user how the unit works and
familiarise him or her with its use.
- Advise the user about possible hazards
(high water temperature)
- Hand over these instructions, to be kept
in a safe place.
Cause
The water flow volume required for the
unit to turn on has not been reached.
- The shower head is blocked with dirt or
limescale.
- Flow volume too low.
- ELSD activated
The water flow volume required for the unit
to turn on has not been reached.
- Filter in the cold water connection pipe
blocked with dirt.
- Water pressure not enough

2.7 Service note

When carrying out any work,
isolate the unit from the mains
and shut off the water connection.
- Clean the filter
Remove filter (14) and clean. Re-assemble
in reverse order.
3. Guarantee
For guarantees please refer to the
respective terms and conditions of supply
for your country.
The installation, electrical connec-
tion and first operation of this
appliance should be carried out by a
qualified installer.
The company does not accept liability for
failure of any good supplied which have not
been installed and operated in accordance
with the manufacture's instructions.
Rectification
- Clean shower head or remove limescale.
- Increase flow volume.
- Press "Reset" - button.
- Clean the filter after shutting off the cold
water intake.
- Increase mains pressure