Maintenance
64

Fuel system, bleeding

TAD550GE, TAD750GE, TAD751GE, TAD752GE,
TAD753GE, TAD754GE
1
Open the hand pump (1), by pressing it in and
turning it counter-clockwise.
2
Purge the fuel system by pumping at least 250
strokes on the hand pump.
Pump rapidly, to maintain pressure in the pump.
NOTICE! Purging is not complete while
resistance is felt in the pump.
3
Close the hand pump (1) by pressing it in and
turning it clockwise.
4
Start the engine and let it idle for at least 5
minutes, before speed is increased.