Configuration As Guard Unit Of "General Door Panels" And Operation - golmar CE-ART 7W/G2+ GUARD UNIT User Manual

Wi-fi connectivity 2-wire installation
Hide thumbs Also See for CE-ART 7W/G2+ GUARD UNIT:
Table of Contents

Advertisement

CE-ART 7W/G2+ GUARD UNIT
CE-ART 7W/G2+ GUARD UNIT
Settings as guard unit of "general door panels"
The guard unit/s to set as guard unit of "general door panels" (up to 4 guard units), must be configured with
address 1 and as
telephones and general door panels (the building/s door panels with EL632/G2+ SE sound module, must be
disconnected and the monitor/s of apartment 1 of differents buildings must be set with a
different to 1). Then enter the special code
guard unit/s with address 1 will be now a guard unit/s of general door panels with
symbol
at the top
the monitor/s of the aparment 1 of the differents buildings). Note: The access door panel will auto-configure the
button P1
on the EL632/G2+ SE module with the
Important: Guard unit compatible with the EL632/G2+ SE V08 + 6587.2 and later.
Dip1 to Dip7: Sets the guard unit with address 1, (Dip1 to ON and dip2-Dip7 to OFF).
Address 1
ON
1
2
3
4
5
6
7
Dip8: This activates the end-of-line resistance in the ON position. Activate it in
ends. Deactivate it only in intermediate
Dip
8
to
ON
ON
1
2
3
4
5
6
7
8
Note: If there are more than one of the guard unit (up to 4 guard units), to define whether the guard unit is master or
slave (see special codes page 27 to 28).
door panels").
Important: Only the master guard unit can activate the Wi-Fi transmission.
Operation of guard unit of "general door panelsplacas generales":
- The master and slave guard units/s receive the call from the general door panel/s (by pressing button P1 on the
sound module).
- The master and slave guard unit/s can be autoswitch-on with the general door panel 1.
-
The master and slave guard unit/s receive calls from the apartments (by pressing the button below icon
the main menu of the apartment monitor).
- The master and slave guard monitor(s) can be used to call the apartmets (intercom menu contacts list
screen).
- It allows internal intercommunication between the guard units.
-
The master and slave guard units/s ,
panel/s (see special codes page 27 to 28). If the "night mode" of operation is enabled for the guard unit/s (see
special codes page 27 to 28), calls to apartments from the general door panel/s are not captured by the guard
unit/s when the general door panel where the call is made detects "low light conditions".
master slave 1 slave 2
,
,
left
of the main menu screen
8
Dip
8
to
OFF
ON
1
2
3
4
5
6
7
8
,
allow the capture of apartment calls make from the selected general door
or
slave 3 , the installation must be connected all guard units, monitors,
.
"5002
" in a master monitor (see special codes on pages 27 to 28), the
(connect the building/s door panels and now set with adress 1
call address 129
.
guard units
.
Note:
Only one master guard unit for (concierge "building" or "general
"free"
address call
address 129
and displaying the
guard unit
where the bus cable
,
or lost call
7
on

Advertisement

Table of Contents
loading

Table of Contents