Installation
5.4.2 Connector systems (VTD-60.05-K5C-S)
In order to operate the motor with nominal current, the cross-sections of the connecting cables must be
configured to the respective operating current in accordance with applicable national standards.
The maximum possible cross-sections of the connectors must be used for the nominal values of the device. A
NOTE
minimum cable length of 20 cm must be adhered to.
Using tools not specified by the manufacturer can impair the reliability of the crimp connection and can even
cause a failure.
NOTE
For more information, see
www.jst.com
Connecting the crimp connectors of JST PH series (interface X1)
The following overview shows which conductor cross-sections can be used with the I/O connector:
Terminal
Designation/item no.
• Crimp housing - PHR-15
X1
• Crimp contact - SPH-002T-P0.5L
• Crimp tool - WC-240
Processing of the MOLEX Microfit 3.0 crimp connectors (interface X2)
Terminal
Designation/item no.
• Crimp housing - 43645-0500
X1
• Crimp contact - 43030-0001
• Crimp tool - 63819-0000
Item no.: HAB 100177146 - 000 · ENU · Change 1.1 · Approved 2023-02-21
28/37
and www.molex.com.
Cable cross-section d
(AWG)
(mm
)
2
AWG 24 ... 30
0.05 ... 0.22
Cable cross-section d
(AWG)
(mm
)
2
AWG 20 ... 24
0.2 ... 0.519
A
Insulation
d
D
d = core cross-section
D = Diameter of
insulation
A = stripping length
Max. insulation
cross-section D
(mm)
1.5
A
Insulation
d
D
d = core cross-section
D = Diameter of
A = stripping length
Max. insulation
cross-section D
(mm)
1.85
Control electronics
Control electronics
VTD-60.XX-K5C-S
VTD-60.XX-K5C-S
Stripping length mm
~1.5 ... 2
insulation
Stripping length mm
~2.54 ... 2.92