ebm-papst VTD-60.05-K5C-S Translation Of The Original Operating Instructions page 27

Control electronics
Table of Contents

Advertisement

Control electronics
Control electronics
VTD-60.XX-K5C-S
VTD-60.XX-K5C-S
Connection of the screw terminals Weidmueller BVZ 7.62 HP (installed in VTD-60.35-K5C-S – interface X1)
The drive controllers use connectors with screw technology for the output side
The following overview shows which conductor cross-sections can be used with the connector:
Terminal
Designation/item no.
X1
BLZ 7.62HP/06 1929970000
Connection of tension spring terminals Weidmueller B2CF 3.5 (installed in VTD-60.13-K5C-S, VTD-60.35-K5C-S -
interfaces X2, X3, X4)
The drive controllers use connectors with tension spring technology for single/fine-wire conductors
The following overview shows which conductor cross-sections can be used with the connector:
Terminal
Designation/item no.
X2
B2CF 3.5/14 1277520000
X3
B2CF 3.5/12 1277510000
X4
B2CF 3.5/6 1277470000
d
Single-wire
H05(07)V-U
0.2 to 6
d
Insulation
Single/fine-wire conductor
Conductor with wire-end ferrule
Insulation
Single-wire
H05(07)V-U
0.14 to 1.5
Item no.: HAB 100177146 - 000 · ENU · Change 1.1· Approved 2023-02-21
Single/fine-wire conductor
Insulation
Insulation
Conductor with wire-end ferrule
Terminal area (cross-section d) mm
Fine-wire
Fine-wire
with wire-end
H05(07)V-K
ferrule
0.5 to 6
0.25 to 6
d = core cross-section
Terminal area (cross-section d) mm
Fine-wire
Fine-wire
with wire-end
H05(07)V-K
ferrule
0.14 to 1.5
0.14 to 1.5
Installation
d = core cross-section
2
Fine wire
Stripping
with wire-
length mm
end ferrule
and plastic
collar
0.25 to 6
12
2
Fine wire
Stripping
with wire-
length mm
end ferrule
and plastic
collar
0.14 to 1
10
27/37