ebm-papst CN1090 Operating And Maintenance Instructions Manual

ebm-papst CN1090 Operating And Maintenance Instructions Manual

Demand ventilation controller

Advertisement

Quick Links

Operating and Maintenance Instructions
Part No
CN1090
Description
Demand Ventilation Controller (Proportional Control or Constant Pressure)
Issue
Date
G draft
17 Jan 2013
1
5 Feb 2013

Table of Contents

Introduction .............................................................................................................................................................. 2
Specification ............................................................................................................................................................ 2
Fan Compatibility ..................................................................................................................................................... 3
Mechanical Outline .................................................................................................................................................. 3
Safety ...................................................................................................................................................................... 3
EMC Compliance..................................................................................................................................................... 3
ESD ......................................................................................................................................................................... 3
Installation ............................................................................................................................................................... 4
Proportional Band Control, Operation ..................................................................................................................... 5
Proportional Band Control, Commissioning ............................................................................................................. 7
Constant Pressure Control, Operation .................................................................................................................... 9
Constant Pressure Control, Commissioning ............................................................................................................ 9
Fan Run Control: ............................................................................................................................................... 12
Fan Monitor: ...................................................................................................................................................... 12
Alarm Relay:...................................................................................................................................................... 12
Fan Run Relay: ................................................................................................................................................. 12
Fan Maximum Speed Relay (Change-over contacts): ...................................................................................... 12
Power-up Check................................................................................................................................................ 12
Maintenance and Servicing ................................................................................................................................... 12
Use of ebm-papst RM-ECv Controller for local manual control ............................................................................. 12
Terminal Block Use ............................................................................................................................................... 13
PCB Component Location and Live / SELV Circuit ............................................................................................... 14
Declaration of Conformity ...................................................................................................................................... 15
The most recent version of this document may be downloaded at:
210-OMI13277_Iss1.doc
© ebm-papst UK Ltd, 2012
Bug no
1401
1401
First numeric Issue, added CE cert page 1
ORIGINAL INSTRUCTIONS
Chelmsford Business Park Chelmsford Essex CM2 5EZ
Telephone: +44(0)1245468555 Fax: +44(0)1245466336
e-mail
sales@uk.ebmpapst.com
Comments
Identify Live and SELV parts of circuit
www.ebmpapst.co.uk/instructions
Page 1 of 15
CN1090

Advertisement

Table of Contents
loading

Summary of Contents for ebm-papst CN1090

  • Page 1: Table Of Contents

    Fan Maximum Speed Relay (Change-over contacts): ..................12 Power-up Check..............................12 Maintenance and Servicing ........................... 12 Use of ebm-papst RM-ECv Controller for local manual control ................12 Terminal Block Use ............................... 13 PCB Component Location and Live / SELV Circuit ....................14 Declaration of Conformity ............................
  • Page 2: Introduction

    Volt Free Stop/Run control input, (shipped with link to 0V to enable fan run) 0V for Stop/Run Volt Free Select Input 2 0V for Select Input 2 210-OMI13277_Iss1.doc ORIGINAL INSTRUCTIONS Page 2 of 15 © ebm-papst UK Ltd, 2012 Chelmsford Business Park Chelmsford Essex CM2 5EZ Telephone: +44(0)1245468555 Fax: +44(0)1245466336 e-mail sales@uk.ebmpapst.com CN1090...
  • Page 3: Fan Compatibility

    During commissioning, avoid unnecessary contact with electronic components on PCB’s. PCB’s which are Static Sensitive should be stored in anti-static packaging until installed. 210-OMI13277_Iss1.doc ORIGINAL INSTRUCTIONS Page 3 of 15 © ebm-papst UK Ltd, 2012 Chelmsford Business Park Chelmsford Essex CM2 5EZ Telephone: +44(0)1245468555 Fax: +44(0)1245466336 e-mail sales@uk.ebmpapst.com...
  • Page 4: Installation

    Swap to standby fan See Proportional Control Band or Constant Pressure Control sections below for additional settings. 210-OMI13277_Iss1.doc ORIGINAL INSTRUCTIONS Page 4 of 15 © ebm-papst UK Ltd, 2012 Chelmsford Business Park Chelmsford Essex CM2 5EZ Telephone: +44(0)1245468555 Fax: +44(0)1245466336 e-mail sales@uk.ebmpapst.com...
  • Page 5: Proportional Band Control, Operation

    Sensor 2 Voltage Bottom of Top of Control Band 2 Control band 2 Sensor 2 Reading 210-OMI13277_Iss1.doc ORIGINAL INSTRUCTIONS Page 5 of 15 © ebm-papst UK Ltd, 2012 Chelmsford Business Park Chelmsford Essex CM2 5EZ Telephone: +44(0)1245468555 Fax: +44(0)1245466336 e-mail sales@uk.ebmpapst.com CN1090...
  • Page 6 Fan Minimum Speed To invert Speed Control Output (Heating Profile), make S2 setting higher than S3 setting. 210-OMI13277_Iss1.doc ORIGINAL INSTRUCTIONS Page 6 of 15 © ebm-papst UK Ltd, 2012 Chelmsford Business Park Chelmsford Essex CM2 5EZ Telephone: +44(0)1245468555 Fax: +44(0)1245466336 e-mail sales@uk.ebmpapst.com...
  • Page 7: Proportional Band Control, Commissioning

    Connect the Local / Remote / BMS 0-10V control to “0-10V Input, Sensor One“ (J3 pin 3) and “0V“ (J3 pin 6). The external signal 0-10V signal will then control the fan speed over the 0-10V fan speed control voltage range. For local manual control an ebm-papst RM-ECv is recommended. 210-OMI13277_Iss1.doc...
  • Page 8 To invert Speed Control Output (Heating Profile), make S2 setting higher than S3 setting, set S2 to the maximum speed and S3 to the minimum speed. 210-OMI13277_Iss1.doc ORIGINAL INSTRUCTIONS Page 8 of 15 © ebm-papst UK Ltd, 2012 Chelmsford Business Park Chelmsford Essex CM2 5EZ Telephone: +44(0)1245468555 Fax: +44(0)1245466336 e-mail sales@uk.ebmpapst.com...
  • Page 9: Constant Pressure Control, Operation

    Operating and Maintenance Instructions Constant Pressure Control, Operation For use with ebm-papst EC products with 0-10V control input in HVAC constant pressure systems. Can also be used with a pressure tapped inlet ring to provide a constant air volume system The controller uses an external pressure sensor.
  • Page 10 Variable Constant Pressure Control Resistor PID Gain (response speed) Fan Maximum Speed (reserved) (reserved) 210-OMI13277_Iss1.doc ORIGINAL INSTRUCTIONS Page 10 of 15 © ebm-papst UK Ltd, 2012 Chelmsford Business Park Chelmsford Essex CM2 5EZ Telephone: +44(0)1245468555 Fax: +44(0)1245466336 e-mail sales@uk.ebmpapst.com CN1090...
  • Page 11 See table below Rotary DIP Switch S2 & S3 Position Pressure Set-point Voltage 10.0 210-OMI13277_Iss1.doc ORIGINAL INSTRUCTIONS Page 11 of 15 © ebm-papst UK Ltd, 2012 Chelmsford Business Park Chelmsford Essex CM2 5EZ Telephone: +44(0)1245468555 Fax: +44(0)1245466336 e-mail sales@uk.ebmpapst.com CN1090...
  • Page 12: Controller Operation, General: Run Enable Inputs, Led's, Relays, Power-Up Check

    The PCB has no replaceable parts, if a fault develops return the PCB to the manufacturer. Use of ebm-papst RM-ECv Controller for local manual control The ebm-papst RM-ECv Controller can be used to provide a 0-10V manually adjustable control voltage, when supplied from the CN1090 controller “24VDC Unregulated Output, 25mA maximum, sensor supply”.
  • Page 13: Terminal Block Use

    Insert the wire into the lower hole then remove the screwdriver to leave the wire clamped in the terminal. 210-OMI13277_Iss1.doc ORIGINAL INSTRUCTIONS Page 13 of 15 © ebm-papst UK Ltd, 2012 Chelmsford Business Park Chelmsford Essex CM2 5EZ Telephone: +44(0)1245468555 Fax: +44(0)1245466336 e-mail sales@uk.ebmpapst.com...
  • Page 14: Pcb Component Location And Live / Selv Circuit

    Fan2 Run J3 Pin1 Fan1 Alarm Fan2 Alarm J2 Pin1 Rotary DIP Switch position numbering 210-OMI13277_Iss1.doc ORIGINAL INSTRUCTIONS Page 14 of 15 © ebm-papst UK Ltd, 2012 Chelmsford Business Park Chelmsford Essex CM2 5EZ Telephone: +44(0)1245468555 Fax: +44(0)1245466336 e-mail sales@uk.ebmpapst.com CN1090...
  • Page 15: Declaration Of Conformity

    Operating and Maintenance Instructions Declaration of Conformity 13/02/2013 15:08:58 210-OMI13277_Iss1.doc ORIGINAL INSTRUCTIONS Page 15 of 15 © ebm-papst UK Ltd, 2012 Chelmsford Business Park Chelmsford Essex CM2 5EZ Telephone: +44(0)1245468555 Fax: +44(0)1245466336 e-mail sales@uk.ebmpapst.com CN1090...

Table of Contents