Troubleshooting; Tool Maintenance - Paslode IMPULSE PPN-MASTER IM40 Manual

Table of Contents

Advertisement

TROUBLESHOOTING

FIRING THE TOOL
Tool Working Correctly
PROBLEM: No fan and
SOLUTION:
does not fire
• Check for flat battery
• Remove and re-change battery to reset tool
PROBLEM:
SOLUTION:
Fan runs but tool
• Check for empty fuel cell, flat battery, clogged filter or dirty spark plug
does not fire
• Check driver blade returned to top of cylinder
• Clean and oil tool
PROBLEM:
SOLUTION:
Fan runs, tool fires,
• Check for jammed nail
no nail fed.
• Check for collation tape or nail jam, or any foreign body in magazine
• Clean out any oil or material - do not oil magazine
11
PPN-MASTER IM40 MANUAL
ALWAYS REMOVE
BATTERY, FUEL CELL
AND FASTENERS
WHEN SERVICING
OR CLEARING A JAM.

TOOL MAINTENANCE

CLEARING A FASTENER JAM
1
Remove Battery, Fuel cell
and nails
4
5
Remove the magazine
Push or punch the driver
assembly to expose the
blade back to top rest
back of the nose slot (Be
position, using a long
careful the nail follower
punch (if needed)
does not come out of the
magazine channel)
CLEANING THE AIR FILTER
1
2
Use a flat bladed screw
Tap filter gently against
driver to remove cap
timber to remove dust
Please scan QR code for tool specific
maintenance instructions
ALWAYS REMOVE
BATTERY, FUEL CELL
AND FASTENERS
WHEN SERVICING
OR CLEARING A JAM.
2
3
Remove 2 cap screws
Remove Nut from rear of
located on side of
magazine
Magazine securing
magazine to the nose
6
7
With driver blade clear,
Reassemble tool,
operator is free to remove
attached magazine to
jammed or bent nail
nose, replace cap screws
and Nylock nut.
Tool is ready to use.
3
4
Cleaner/Degreaser or soap
Filter will look like new
and water restores the filter
PPN-MASTER IM40 MANUAL
12

Advertisement

Table of Contents
loading

This manual is also suitable for:

B60001

Table of Contents