Mains voltage [V AC]
Mains voltage tolerance
Mains frequency
Max. open circuit power consumption
Nominal output
Charging voltage [V DC]
Arithmetic charging current [A DC]
at 230 V
at 110 V
R.M.S. current [Aeff. DC] *
Battery capacity
Easy Traction
Chargeable cells
On-time
Charging characteristic
Degree of protection
Zeit bis zur Sicherheitsabschaltung
Easy Traction
Length of time before the safety cut-out trips:
* R.M.S. current corresponds to the specifications for conventional battery chargers
The proper functioning of the charger is tested at 5-85% humidity
Component specification: Climate class B
Symbols on
These symbols will also be found on the rating plate in addition to the safety symbols
rating plate
1202
110-230 V
+/-15 %
50/60 Hz
1,5 W
18 W
12 V
1,5 A
0,95 A
2,0 A
Easy
1-85 Ah
6
100 %
IUoU
IP30
Easy
51 h
Read manual before charging
Avoid flames and sparks while charging
Beware! Explosive gases occur while charging.
Battery acid is caustic
For use indoors. Do not expose to rain
Ensure good ventilation while charging
1204
1206
1204 T
1206 T
110-230 V
110-230 V
+/-15 %
+/-15 %
50/60 Hz
50/60 Hz
1,5 W
1,5 W
36 W
48 W
12 V
12 V
3,0 A
4,0 A
1,9 A
2,5 A
4,0 A
6,0 A
2-135 Ah
3-200 Ah 1,5-100 Ah
2-45 Ah
3-65 Ah
6
6
100 %
100 %
IUoU
IUoU
IP30
IP30
29 h
22 h
10 h
10 h
8
2403
6/12
110-230 V
230 V
+/-15 %
+/-15 %
50/60 Hz
50/60 Hz
1,5 W
1,5 W
48 W
18/24 W
24 V
6/12 V
2,0 A
3,0/2,0 A
1,25 A
3,0 A
4,0/3,0 A
2,0-135/
1,5-100 Ah
12
3/6
100 %
100 %
IUoU
IUoU
IP30
IP30
44 h
29 h
10 min
12/24
230 V
+/-15 %
50/60 Hz
1,5 W
36/43 W
12/24 V
3,0/1,8 A
4,0/2,5 A
2,0-135/
1,5-90 Ah
6/12
100 %
IUoU
IP30
44 h
10 min

Advertisement