Prerequisites
Review the System maintenance safety considerations.
If both power modules have failed, shut down the system power.
Procedure
1.
Unplug the power cord from the power module jack on the back of the J2000.
Remove both power cords if replacing both power modules.
2.
Press the power module release tab (top of power module) toward the finger handle while pulling the finger handle
outward to disengage the power module cam.
WARNING: Do not push the PSU tab at the bottom of the power module. The PSU is factory installed and
cannot be removed.
1
2
3.
Using one hand to support the bottom of the power module, let go of the power module release tab, and then pull
the power module out of the J2000 by the finger handle.
4.
Make sure that the replacement power module is in the proper orientation, with the power module release tab at the
top.
5.
With one hand supporting the bottom of the replacement power module, insert the power module into the power
cavity on the rear of the J2000.