Test Run - Grizzly G0592 Owner's Manual

10" x 18" metal-cutting bandsaw
Hide thumbs Also See for G0592:
Table of Contents

Advertisement

Test Run

Once assembly is complete, test run the machine
to ensure it is properly connected to power and
safety components are functioning correctly.
If you find an unusual problem during the test run,
immediately stop the machine, disconnect it from
power, and fix the problem BEFORE operating the
machine again. The Troubleshooting table in the
SERVICE section of this manual can help.
The test run consists of verifying the following: 1)
the main motor runs correctly, 2) the Emergency
Stop/Off button safety feature works correctly,
3) the downfeed limit switch and stop bolt work
correctly, and 4) the coolant pump motor runs
correctly.
Serious injury or death can result from
using this machine BEFORE understanding
its controls and related safety information.
DO NOT operate, or allow others to operate,
machine until the information is understood.
DO NOT start machine until all preceding
setup instructions have been performed.
Operating an improperly set up machine
may result in malfunction or unexpect-
ed results that can lead to serious injury,
death, or machine/property damage.
To test run machine:
1.
Clear all setup tools away from machine.
2.
Use headstock handle to raise headstock all
the way up, then turn feed control dial all the
way right (see Figure 19).
3.
Turn feed rate dial to "1" (see Figure 19).
4.
Press Emergency Stop/Off button (see
Figure 19).
-20-
5.
Connect machine to power by inserting power
cord plug into matching receptacle; power
light will illuminate (see Figure 19).
Emergency
Power
Off/Stop
Light
Button
Figure 19. Initial power controls.
6.
Twist Emergency Stop/Off button clockwise
until it springs out. This resets switch so
machine can start.
7.
Press Start button to turn machine ON (see
Figure 20).
Motor should run smoothly and without
unusual problems or noises.
Start Button
Figure 20. Location of Start button.
8.
Press Emergency Stop/Off button to turn
machine OFF.
9.
WITHOUT resetting Emergency Stop/Off but-
ton, try to start machine by pressing Start but-
ton. Machine should not start.
— If machine does not start, safety feature
of Emergency Stop/Off button is working
correctly.
Model G0592 (Mfd. Since 01/23)
Feed
Feed
Control
Rate
Dial
Dial

Advertisement

Table of Contents
loading

Table of Contents