&F Restore Factory Settings
&K Select Flow Control
&Q Define Communications Mode Option
&S Define DSR Option
&V View Active Configuration
Nokia 6090 AT Command Set
This command restores all the factory settings including all the S-register settings but
does not save them. Command parameters that are reset to their factory defaults are:
S3, S4, S5, E, Q, V, X, &C, &D, +IFC, +ILRR, S25, &S, &Q, +CSCS, S0, S7, S8,
S10, +DS, +DR, +ES, +EB, +EFCS, +ER, +ETBM, S2, S12, +CSTA, +CMOD,
+CBST, +CRLP, +CR, +CRC, +CSNS, +CREG, +CLIP, +CLIR, +COLP, +CCUG,
+CCWA (only <n>), +CUSD (only <n>), +CSSN, +CMEC, +CPBS, +CMEE, +CSMS,
+CPMS, +CMGF, +CSCA, +CSMP, +CSDH, +CSCB, +CNMI.
Syntax:
AT&F[0]
This command selects the local flow control mode. This command changes the same
setting as +IFC. Use of +IFC is recommended. (De facto.)
Syntax:
AT&K[0]
AT&K3
AT&K4
This command defines the dialling and on-line options. (De facto.)
Syntax:
AT&Q[0]
AT&Q2
This command defines how the DSR V.24 signal is handled. (De facto.)
Syntax:
AT&S[0]
AT&S1
This command displays the current values of the S-registers. (V.25ter)
Syntax:
AT&V[0]
AT&V1
AT&V2
Response is for V1 and V2:
E1 Q0 V1 X5 &C1 &D2 &Q0 &S1
S00:000 S01:000 S02:043 S03:013 S04:010 S05:008 S07:060 S08:002
S10:100 S12:050 S14:010 S21:112 S22:016 S25:000 S27:000 S34:002
S35:007 S38:000 S39:000 S40:000 S41:001 S42:061 S43:061 S44:048
S45:006 S46:000 S47:000 S48:000
Restore factory settings.
Disable flow control.
Set hardware flow control (CTS/RTS).
Default option.
Set software flow control (XON/XOFF)
Enable normal asynchronous operation.
Default option.
Enable DTR controlled dial. DTR OFF to
ON causes a call to be made to the
number stored in the TA dial slot zero.
DTR ON to OFF hangs up the call.
Keep DSR always ON.
Enable normal DSR usage. Default
option.
View active configuration. (All command
parameter values defined under &F and
&Y settings).
Show settings in stored profile 0. (All
command parameter values defined under
&W).
Show settings in stored profile 1. (All
command parameter values defined under
&W).